Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: TEXAS MEDICAL INDUSTRIES, INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of TEXAS MEDICAL INDUSTRIES, INC. in 1409 INDUSTRIAL PARK, ROYSE CITY, TX 75189 (NAICS 339113). OSHA activity number 344597372.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Texas Medical Industries, INC. for free Get an email when a new federal OSHA severe-injury report for Texas Medical Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1409 INDUSTRIAL PARK
City
ROYSE CITY
State
TX
ZIP
75189
Mailing
1409 INDUSTRIAL PARK, ROYSE CITY, TX 75189
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339113
Employees
15
Ownership type
Private (A)

1 citation on file for this inspection.

1910.212 A01

Repeat Gravity 5 3 instances 3 exposed
Issued
Apr 10, 2020
Abate by
May 6, 2020
Penalty
Initial $6,169 · Current $3,084 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:     (a) On or about January 29, 2020 and times prior thereto in the Machine Shop, Metal Fabrication Area,  a Wilton vertical belt sander,  where employees were exposed to amputation and flying metal chip and spark hazards from the belt sander.     (b) On or about December 6, 2020 and times prior thereto in the Machine Shop, Metal Fabrication Area, a Jet Drill Press, where employees were exposed to amputation and flying metal chip hazards from the rotating drill.     (c) On or about December 6, 2020 and times prior thereto in the Machine Shop, Metal Fabrication Area, Jet Drill Press, where employees were exposed to amputation and flying metal chip hazards from the rotating drill.     Texas Medical Industries, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1) , which was contained in OSHA inspection number 1383463, citation number 1, item number 4 and was affirmed as a final order on August 13, 2019, with respect to a workplace located at 1409 Industrial Park Royse City, TX 75189.
Recent events (2)
  • · I (R) $3084
  • · Z (R) $6169

View Texas Medical Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344597372.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.