PASSAIC, NJ —
OSHA Inspection: 441 PASCACK RD LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of 441 PASCACK RD LLC in 2 MARKET ST, PASSAIC, NJ 07055 (NAICS 236115). OSHA activity number 344599444.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- 441 PASCACK RD LLC
- Site address
- 2 MARKET ST
- City
- PASSAIC
- State
- NJ
- ZIP
- 07055
- Mailing
- 386 RT. 59 SUITE 201, AIRMONT, NY 10952
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 5
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.252 B
- Issued
- Feb 7, 2020
- Penalty
- Initial $1,735 · Current $800 Reduced
General-duty citation text
29 CFR 1926.252(b): When debris was dropped through holes in the floor without the use of chutes, the area onto which the material was dropped was not completely enclosed with barricades not less than 42 inches high and not less than 6 feet back from the area. a) Interior - Drop Area: Employee engaged in cleaning activities was dropping materials down several stories without barricades and signs in the lower levels, on or about 10/18/19
Recent events (3)
- — J (S) $800
- — C (S) $1735
- — Z (S) $1735
1926.350 A09
- Issued
- Feb 7, 2020
- Penalty
- Initial $1,735 · Current $800 Reduced
General-duty citation text
29 CFR 1926.350(a)(9): Compressed gas cylinder(s) were not secured in an upright position: a) Exterior of building - Next to Portable Toilet: Oxygen and acetylene cylinders were not secured for several weeks, on or about 10/17/19
Recent events (3)
- — J (S) $800
- — C (S) $1735
- — Z (S) $1735
1926.350 A10
- Issued
- Feb 7, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel-gas cylinder or combustible materials (especially oil or grease), a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour. a) Exterior of building - Next to Portable Toilet: Oxygen and acetylene cylinders were not secured and were stored next to each other without a noncombustible barrier between them for several weeks, on or about 10/17/19
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.404 B01 I
- Issued
- Feb 7, 2020
- Penalty
- Initial $1,735 · Current $800 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) Interior Stairway: Employee engaged in cleaning activities was exposed to electric shock while utilizing electric equipment not connected to GFCI, on or about 10/17/19
Recent events (3)
- — J (S) $800
- — C (S) $1735
- — Z (S) $1735
1926.405 A02 II E
- Issued
- Feb 7, 2020
- Penalty
- Initial $1,735 · Current $800 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(E): All lamps for temporary illumination were not protected from accidental contact or breakage: a) Interior Stairway: Several of the energized temporary lights were not protected by cages, on or about 10/17/19
Recent events (3)
- — J (S) $800
- — C (S) $1735
- — Z (S) $1735
1926.1052 A03
- Issued
- Feb 7, 2020
- Penalty
- Initial $1,735 · Current $800 Reduced
General-duty citation text
29 CFR 1926.1052(a)(3): Variations in riser height or tread depth were over 1/2-inch (0.6 cm) in any stairway system: a) Exterior of Building - Market St Entrance: Employee was utilizing a makeshift loose, uneven concrete block stairway to access the building, on or about 10/17/19
Recent events (3)
- — J (S) $800
- — C (S) $1735
- — Z (S) $1735
1926.1052 C03 I
- Issued
- Feb 7, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(3)(i): The height of stairrails installed after March 15, 1991, was less than 36 inches (91.5 cm) from the upper surface of the stairrail system to the surface of thread, in line with the face of the riser at the forward edge of the tread. a) Exterior of Building - Market St Entrance: Employee was utilizing a makeshift loose, uneven concrete block stairway to access the building with a handrail approximately 8" above the tread, on or about 10/17/19
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 236115)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344599444.