Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: ATLASTA SOLAR CENTER, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ATLASTA SOLAR CENTER, LLC in 2967 OUTLOOK RD, MONTROSE, CO 81401 (NAICS 221114). OSHA activity number 344600960.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atlasta Solar Center, LLC for free Get an email when a new federal OSHA severe-injury report for Atlasta Solar Center, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2967 OUTLOOK RD
City
MONTROSE
State
CO
ZIP
81401
Mailing
1111 S 7TH ST, GRAND JUNCTION, CO 81501
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221114
Employees
3
Ownership type
Private (A)

1 citation on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 6, 2020
Abate by
Mar 4, 2020
Penalty
Initial $6,747 · Current $3,374 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):      (a) On or about January 29, 2020, the employer did not ensure that its employees were protected from falls while working at heights greater than 6 feet. An employee of Atlasta Solar Center, LLC was exposed to fall hazards greater than 12 feet while engaged in residential solar panel installation activities with no fall protection systems in place.       Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").     .
Recent events (2)
  • · I (S) $3374
  • · Z (S) $6747

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344600960.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.