CHICAGO, IL —
OSHA Inspection: PACKERS SANITATION SERVICES, INC., LTD. DBA PSSI
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PACKERS SANITATION SERVICES, INC., LTD. DBA PSSI in 4201 S. ASHLAND AVE., CHICAGO, IL 60609 (NAICS 561720). OSHA activity number 344602776.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PACKERS SANITATION SERVICES, INC., LTD. DBA PSSI
- Site address
- 4201 S. ASHLAND AVE.
- City
- CHICAGO
- State
- IL
- ZIP
- 60609
- Mailing
- 3681 PRISM, KIELER, WI 53812
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561720
- Employees
- 65
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 D
- Issued
- May 27, 2020
- Abate by
- Jun 8, 2020
- Penalty
- Initial $13,494 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a. On or about January 23, 2020, on the Blender-Versatherm, the operator was exposed to machine hazards associated with moving parts when cleaning the blender-versatherm with a water hose. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $13494
More inspections at Packers Sanitation Services, INC., LTD. DBA Pssi
View Packers Sanitation Services, INC., LTD. DBA Pssi's full OSHA safety record →
More inspections in this industry (NAICS 561720)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344602776.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.