Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U. S. DEPARTMENT OF THE INTERIOR, U. S. BUREAU OF RECLAMATION

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of U. S. DEPARTMENT OF THE INTERIOR, U. S. BUREAU OF RECLAMATION in 1200 PARK STREET, BOULDER CITY, NV 89006 (NAICS 924120). OSHA activity number 344606330.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U. S. Department of the Interior, U. S. Bureau of Reclamation — free Get an email when a new federal OSHA severe-injury report for U. S. Department of the Interior, U. S. Bureau of Reclamation is published. One employer, no account, unsubscribe in one click.
Site address
1200 PARK STREET
City
BOULDER CITY
State
NV
ZIP
89006
Mailing
P.O. BOX 61470, BOULDER CITY, NV 89006
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
120
Ownership type
D

1 citation on file for this inspection.

1910.253 B04 III

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 11, 2020
Penalty
Initial $0 · Current $0

Hazardous substances 0070X100

29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  (A)  On or about February 4, 2020, and at times prior to that date, for employees exposed to potential fire hazards where oxygen and acetylene tanks that were stored within one foot of each other at or near 1200 Park Street in Boulder City, Nevada.
Recent events (1)
  • — Z (S) $0

View U. S. Department of the Interior, U. S. Bureau of Reclamation's full OSHA safety record →