CHARLESTON, WV —
OSHA Inspection: SUTTER ROOFING & METAL CO., INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SUTTER ROOFING & METAL CO., INC. in 1031 QUARRIER ST, CHARLESTON, WV 25301 (NAICS 238160). OSHA activity number 344607932.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUTTER ROOFING & METAL CO., INC.
- Site address
- 1031 QUARRIER ST
- City
- CHARLESTON
- State
- WV
- ZIP
- 25301
- Mailing
- P.O. BOX 2036, CLARKSBURG, WV 26302
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 200
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B10
- Issued
- Jul 28, 2020
- Abate by
- Aug 5, 2020
- Penalty
- Initial $8,675 · Current $0 Reduced
General-duty citation text
9 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. (a) Atlas Building, Roof - On or about 1/29/20, employees performing roofing work near an exposed edge were not provided with adequate fall protection, exposing employees to fall hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $8675
1926.502 D15
- Issued
- Jul 28, 2020
- Abate by
- Aug 5, 2020
- Penalty
- Initial $0 · Current $4,338
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person. (a) Atlas Building, Roof - On or about 1/29/20, employees performing roofing work were using an anchorage which was not properly installed in accordance with the manufacturers instruction to support at least 5000 pounds, exposing employees to fall hazards.
Recent events (2)
- — I (O) $4337.5
- — Z (S) $0
1926.502 F02 I
- Issued
- Jul 28, 2020
- Abate by
- Aug 5, 2020
- Penalty
- Initial $0 · Current $4,338
General-duty citation text
29 CFR 1926.502(f)(2)(i): The rope, wire, or chain was not flagged at not more than 6-foot (1.8 m) intervals with high-visibility material; (a) Atlas Building, Roof - On or about 1/29/20, employees performing roofing work were using a warning line system which was not flagged, exposing employees to fall hazards.
Recent events (2)
- — I (O) $4337.5
- — Z (S) $0
1926.152 D02
- Issued
- Jul 28, 2020
- Abate by
- Aug 4, 2020
- Penalty
- Initial $13,880 · Current $0 Reduced
General-duty citation text
29 CFR 1926.152(d)(2): A portable fire extinguisher having a rating of not less than 20-B units was not located between 25 feet and 75 feet from flammable liquid storage area(s) located outside: (a) Atlas Building, Roof - On or about 1/29/20, portable fire extinguishers were located less than 25 feet from where flammable liquids were stored outside, exposing employees to fire hazards. Sutter Roofing & Metal Co. Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1428955, citation number 1, item number 1/b and was affirmed as a final order on 11/08/2019, with respect to a workplace located at 300 Spruce St, Morgantown, WV.
Recent events (2)
- — I (R) $0
- — Z (R) $13880
More inspections at Sutter Roofing & Metal CO., INC.
View Sutter Roofing & Metal CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344607932.