OSHA Inspection: SUTTER ROOFING & METAL CO., INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SUTTER ROOFING & METAL CO., INC. in 1031 QUARRIER ST, CHARLESTON, WV 25301 (NAICS 238160). OSHA activity number 344607932.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sutter Roofing & Metal CO., INC. — free Get an email when a new federal OSHA severe-injury report for Sutter Roofing & Metal CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
1031 QUARRIER ST
City
CHARLESTON
State
WV
ZIP
25301
Mailing
P.O. BOX 2036, CLARKSBURG, WV 26302
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
200
Ownership type
A

4 citations on file for this inspection.

1926.501 B10

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Jul 28, 2020
Abate by
Aug 5, 2020
Penalty
Initial $8,675 · Current $0 Reduced
9 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.      (a) Atlas Building, Roof - On or about 1/29/20, employees performing roofing work near an exposed edge were not provided with adequate fall protection, exposing employees to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8675

1926.502 D15

Other-than-serious 1 instance 2 exposed
Issued
Jul 28, 2020
Abate by
Aug 5, 2020
Penalty
Initial $0 · Current $4,338
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person.    (a) Atlas Building, Roof - On or about 1/29/20, employees performing roofing work were using an anchorage which was not properly installed in accordance with the manufacturers instruction to support at least 5000 pounds, exposing employees to fall hazards.
Recent events (2)
  • — I (O) $4337.5
  • — Z (S) $0

1926.502 F02 I

Other-than-serious 1 instance 5 exposed
Issued
Jul 28, 2020
Abate by
Aug 5, 2020
Penalty
Initial $0 · Current $4,338
29 CFR 1926.502(f)(2)(i): The rope, wire, or chain was not flagged at not more than 6-foot (1.8 m) intervals with high-visibility material;     (a) Atlas Building, Roof - On or about 1/29/20, employees performing roofing work were using a warning line system which was not flagged, exposing employees to fall hazards.
Recent events (2)
  • — I (O) $4337.5
  • — Z (S) $0

1926.152 D02

Deleted Repeat Gravity 5 1 instance 5 exposed
Issued
Jul 28, 2020
Abate by
Aug 4, 2020
Penalty
Initial $13,880 · Current $0 Reduced
29 CFR 1926.152(d)(2): A portable fire extinguisher having a rating of not less than 20-B units was not located between 25 feet and 75 feet from flammable liquid storage area(s) located outside:  (a) Atlas Building, Roof - On or about 1/29/20, portable fire extinguishers were located less than 25 feet from where flammable liquids were stored outside, exposing employees to fire hazards.  Sutter Roofing & Metal Co. Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1428955, citation number 1, item number 1/b and was affirmed as a final order on 11/08/2019, with respect to a workplace located at 300 Spruce St, Morgantown, WV.
Recent events (2)
  • — I (R) $0
  • — Z (R) $13880