SMYRNA, GA ·
OSHA Inspection: ARG CONTRACTING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ARG CONTRACTING, INC. in (LOT #2) 2467 DAVIS DRIVE, SMYRNA, GA 30080 (NAICS 238130). OSHA activity number 344608989.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARG CONTRACTING, INC.
- Site address
- (LOT #2) 2467 DAVIS DRIVE
- City
- SMYRNA
- State
- GA
- ZIP
- 30080
- Mailing
- 2301 OLD SPRING ROAD, SMYRNA, GA 30080
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- Mar 4, 2020
- Penalty
- Initial $2,313 · Current $1,388 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles: a) New residential construction located on Lot #2, Second level and top plates: On or about 02/05/2020, and at times prior, the employer exposed employees to struck-by hazards while operating circular saws and pneumatic framing nail guns, in that employees were not provided with protective eyewear while engaged in framing activities.
Recent events (2)
- · I (S) $1387.8
- · Z (S) $2313
1926.304 D
- Issued
- Mar 4, 2020
- Penalty
- Initial $4,048 · Current $2,429 Reduced
General-duty citation text
29 CFR 1926.304(d): Portable, power-driven circular saw(s) were not equipped with a guard above and below the base plate or shoe: a) New residential construction located on Lot #2, First and Second levels: On or about 02/05/2020, and at times prior, the employer exposed employees to severe laceration/amputation hazards while operating circular saws, in the all three saws used on site had inoperable lower guards as the lower guard was shimmed to the upper guard to prevent the lower guard from retracting after a cut was made.
Recent events (2)
- · I (S) $2428.8
- · Z (S) $4048
1926.501 B13
- Issued
- Mar 4, 2020
- Abate by
- Mar 16, 2020
- Penalty
- Initial $4,048 · Current $2,429 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) New residential construction located on Lot #2, First and Second levels: On or about 02/05/2020, and at times prior, the employer exposed employees to fall hazards of approximately 21-feet, 5-inches to the lower level, in that fall protection was not used while walking the outside top plates installing roof trusses.
Recent events (2)
- · I (S) $2428.8
- · Z (S) $4048
1926.403 B01
- Issued
- Mar 4, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: a) New residential construction located on Lot #2, First level: On or about 02/05/2020, and at times prior, the employer failed to inspect all of the electrical cords prior to the start of the work shift, in that a 50-ft. extension cord used to power a Makita Circular had a damaged protective casing and a damaged strain relief which was not repaired or removed from service.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 238130)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344608989.