SOUTH BOSTON, MA ·
OSHA Inspection: SEAPORT RESIDENTIAL LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of SEAPORT RESIDENTIAL LLC in 340 W. 2ND STREET, SOUTH BOSTON, MA 02127 (NAICS 236116). OSHA activity number 344613807.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SEAPORT RESIDENTIAL LLC
- Site address
- 340 W. 2ND STREET
- City
- SOUTH BOSTON
- State
- MA
- ZIP
- 02127
- Mailing
- P.O. BOX 52514, BOSTON, MA 02205
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 1
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.304 H01
- Issued
- Feb 25, 2020
- Penalty
- Initial $4,048 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut:Note: See paragraph (i)(1) of this section for additional requirements for hand-fed crosscut table saws. Location: Unit 3 The DeWalt DWE780 table saw blade was unguarded. A subcontractor employee suffered a finger amputation while using the unguarded saw.
Recent events (2)
- · I (S) $1000
- · Z (S) $4048
1926.1052 C01 I
- Issued
- Feb 25, 2020
- Penalty
- Initial $2,313 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: Location: Stairway used to access Unit 3. The stairway lacked at least one handrail.