WASHINGTON, DC —
OSHA Inspection: LUIS CONSTRUCTION, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of LUIS CONSTRUCTION, INC. in 2891 AUDUBON TERRACE, NW, WASHINGTON, DC 20008 (NAICS 236118). OSHA activity number 344624937.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LUIS CONSTRUCTION, INC.
- Site address
- 2891 AUDUBON TERRACE, NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20008
- Mailing
- 501 WILLIAMSBURG ROAD, STERLING, VA 20164
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.21 B02
- Issued
- Jun 18, 2020
- Abate by
- Jun 30, 2020
- Penalty
- Initial $4,048 · Current $4,048
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) Site - Employees were not provided with training on how to recognize a hazard while in an excavation where shear walls were up to 9 feet in depth and not protected from a cave-in hazard, on or about 02/11/2020. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $4048
1926.651 K01
- Issued
- Jun 18, 2020
- Abate by
- Jun 24, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not made after every rainstorm or other hazard increasing occurrence: a) Site - A competent person failed to make an inspection of an excavation that was up to 9 feet in depth where rain had saturated the ground and an employee was standing near an unprotected shear wall, on or about 02/11/2020. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $0
1926.652 A01
- Issued
- Jun 18, 2020
- Abate by
- Jun 24, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): a) Site - Employees were in an excavation that measured 50 wide, 100 in length and up to 9 feet in depth and were not protected from a cave-in hazard, on or about 02/11/2020. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $0
More inspections at Luis Construction, INC.
View Luis Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236118)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344624937.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.