Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: VIVINT SOLAR HOLDINGS, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of VIVINT SOLAR HOLDINGS, INC. in 3548 LOUIS STREET, FRANKLIN PARK, IL 60131 (NAICS 221119). OSHA activity number 344625769.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vivint Solar Holdings, INC. — free Get an email when a new federal OSHA severe-injury report for Vivint Solar Holdings, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3548 LOUIS STREET
City
FRANKLIN PARK
State
IL
ZIP
60131
Mailing
58 SAND CREEK LANE, TOMS RIVER, NJ 08753
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221119
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Repeat Gravity 5 1 instance 3 exposed
Issued
Jun 12, 2020
Penalty
Initial $84,821 · Current $46,000 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     a) On February 12, 2020, employees were installing solar panels on the roof of a residential structure without the use fall protection, and were exposed to fall hazards of approximately 11.5 feet to the ground below.    Vivint Solar, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1181512, citation number 1, item number 1 and was affirmed as a final order on May 14, 2017 with respect to a workplace located at 515 Union Ave. in Lakehurst, NJ 08733.    Vivint Solar, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1410198, citation number 1, item number 1 and was affirmed as a final order on October 8, 2019 with respect to a workplace located at 29 Tecumseh Street in Longmeadow, MA 01106.
Recent events (2)
  • — I (R) $46000
  • — Z (R) $84821

1926.503 B01

Other-than-serious 1 instance 4 exposed
Issued
Jun 12, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.  a) On or about February 12, 2020, the employer did not maintain written fall protection certification records for employees that were installing solar panels on an existing one story single family home.   No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Vivint Solar Holdings, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344625769.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.