CANANDAIGUA, NY ·
OSHA Inspection: CORBY'S PRECISION COLLISION AT ONTARIO IMPORTS, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of CORBY'S PRECISION COLLISION AT ONTARIO IMPORTS, INC. in 2460 STATE ROUTE 332, CANANDAIGUA, NY 14424 (NAICS 811121). OSHA activity number 344627005.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CORBY'S PRECISION COLLISION AT ONTARIO IMPORTS, INC.
- Site address
- 2460 STATE ROUTE 332
- City
- CANANDAIGUA
- State
- NY
- ZIP
- 14424
- Mailing
- 2460 STATE ROUTE 332, CANANDAIGUA, NY 14424
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 15
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 13, 2020
- Penalty
- Initial $3,277 · Current $2,458 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck by hazard: a) Mechanical Lift Area, on or about 2/12/2020: Frequent and periodic inspections of the Rotary Automotive Lift, Model No. SP0A9-200, Serial No. SPA01A2935 were not being conducted in that the last inspection was done in October 2016.
Recent events (2)
- · I (S) $2457.75
- · Z (S) $3277
1910.101 B
- Issued
- Apr 13, 2020
- Penalty
- Initial $1,671 · Current $1,253 Reduced
General-duty citation text
29 CFR 1910.101(b): Section 3.4.4, Compressed Gas Association Pamphlet P-11965, as adopted by 29 CFR 1910.101(b): Compressed gas cylinder(s) in use were not properly supported to prevent them from being knocked over: a) Paint Booth and Office Area Aisle-way, on or about 2/12/2020: Three compressed gas cylinders: Oxygen; Acetylene and Argon were not secured to prevent them from being knocked over.
Recent events (2)
- · I (S) $1253.25
- · Z (S) $1671
1910.253 B04 III
- Issued
- Apr 13, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire resistance rating of at least one-half hour: a) Paint Booth and Office Area Aisle-way, on or about 2/12/2020: Cylinder Storage Area had one acetylene tank and one oxygen tank stored together.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.106 E06 I
- Issued
- Apr 13, 2020
- Penalty
- Initial $1,671 · Current $1,253 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions against the ignition of flammable vapors were not taken: a) Mixing Room, on or about 2/12/2020: Employees adding waste material to a 15 gallon drum of flammable waste without grounding the 15 gallon container.
Recent events (2)
- · I (S) $1253.25
- · Z (S) $1671
1910.37 B02
- Issued
- Apr 13, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "EXIT": a) Parts Room, on or about 2/12/2020: Exit door was not marked by a sign reading "EXIT".
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.157 C01
- Issued
- Apr 13, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Tear Down Bay Area, on or about 2/12/2020: A portable fire extinguisher was blocked by five 55 gallon drums and a Snap-on tire machine.