Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: ELECTROTEK CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ELECTROTEK CORPORATION in 7745 S. 10TH STREET, OAK CREEK, WI 53154 (NAICS 334412). OSHA activity number 344636956.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Electrotek Corporation for free Get an email when a new federal OSHA severe-injury report for Electrotek Corporation is published. One employer, no account, unsubscribe in one click.
Site address
7745 S. 10TH STREET
City
OAK CREEK
State
WI
ZIP
53154
Mailing
7745 S. 10TH STREET, OAK CREEK, WI 53154
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334412
Employees
120
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 10, 2020
Abate by
Aug 14, 2020
Penalty
Initial $7,374 · Current $5,162 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.   a. On or about February 7, 2020, the employer did not develop or document machine specific energy control procedures for employees that were engaged in service and maintenance activities on equipment, such as, but not limited to, DES and SES line auxiliary equipment, motors, and pumps, where the unexpected energizing, start up or release of stored energy could occur and cause injury.
Recent events (2)
  • · I (S) $5161.8
  • · Z (S) $7374

1910.212 A05

Serious Gravity 5 2 instances 2 exposed
Issued
Jul 10, 2020
Abate by
Jul 29, 2020
Penalty
Initial $7,374 · Current $5,162 Reduced
29 CFR 1910.212(a)(5): Exposure of blades. When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the blades shall be guarded. The guard shall have openings no larger than one-half (1/2) inch.  a.  On or about February 7, 2020, located at the backside of the SES line, two motor cooling fans did not have a guard installed, exposing employees to an amputation injury.  The fans were approximately 12 inches from the floor level.    b. On or about February 7, 2020, located at the backside of the DES line, a motor cooling fan did not have a guard installed, exposing employees to an amputation injury.  The fans were approximately 32 inches from the floor level.
Recent events (2)
  • · I (S) $5161.8
  • · Z (S) $7374

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 10, 2020
Abate by
Jul 29, 2020
Penalty
Initial $5,899 · Current $4,129 Reduced
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.  a. On or about February 7, 2020, located near the end of DES line, a relocatable power tap was used as a substitute for fixed wiring for supplying power to hazardous chemical transfer pumps. The relocatable power tap was not used in accordance with the UL listing and exposing employees to a potential fire hazard.
Recent events (2)
  • · I (S) $4129.3
  • · Z (S) $5899

1910.303 B07 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 10, 2020
Abate by
Jul 29, 2020
Penalty
Initial $5,899 · Current $4,129 Reduced
29 CFR 1910.303(b)(7)(iv): There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.  a. On or about February 7, 2020, in the HAL room, there was a 480 volt disconnect that supplied electrical power, in part to the HAL pre-clean machine. The electrical disconnect switch located on the exterior of the electrical panel was broken off, which did not allow safe operation if an emergency occurred with the equipment and electrical power had to be immediately removed.
Recent events (2)
  • · I (S) $4129.3
  • · Z (S) $5899

1910.303 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 10, 2020
Abate by
Jul 29, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.   a. On or about February 7, 2020, in the HAL room behind accumulator #8, there was a 480 volt disconnect that supplied electrical power, in part to the hot air solder leveling equipment. The electrical disconnect was blocked by accumulator #8, stored chemical containers, and supply boxes. These blockages did not allow access to the electrical disconnect if an emergency occurred with the equipment and electrical power had to be immediately removed.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Electrotek Corporation's full OSHA safety record →