Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SEHLHORST EQUIPMENT SERVICES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SEHLHORST EQUIPMENT SERVICES, INC. in 6000 GLENWAY AVE., CINCINNATI, OH 45211 (NAICS 238220). OSHA activity number 344638838.

Watch Sehlhorst Equipment Services, INC. — free Get an email when a new federal OSHA severe-injury report for Sehlhorst Equipment Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6000 GLENWAY AVE.
City
CINCINNATI
State
OH
ZIP
45211
Mailing
4450 MONROE ST., HOOVEN, OH 45033
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
40
Ownership type
A

3 citations on file for this inspection.

1926.651 C02

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $9446.00 · Current $0.00 Reduced
29 CFR 1926.651(c)(2): Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.  On February 19, 2020, located on the west side of a fenced-in commercial parking lot, an employee was observed working in an excavation that was 5'-10" in-depth that had no suitable means of access or egress located within 25' of the work area within the excavation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9446

1926.651 K01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $9446.00 · Current $4000.00 Reduced
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.     On February 19, 2020, located on the west side of a fenced-in commercial parking lot, an employee working inside an excavation 5'-10" in-depth as there were no inspections conducted before the work beginning by a competent person to evaluate the need of a protective system and suitable means of access or egress of the excavation.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $9446

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $9446.00 · Current $0.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:    On February 19, 2020, located on the west side of a fenced-in commercial parking lot, an employee working in an excavation greater than 5 in-depth without adequate protection against cave-ins, in that the walls of the excavation were not properly sloped shored, benched or otherwise adequately protected against collapse.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9446