KEENE, NH —
OSHA Inspection: UNION POWER STUCCO LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of UNION POWER STUCCO LLC in KEY ROAD, KEENE, NH 03431 (NAICS 238140). OSHA activity number 344640594.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNION POWER STUCCO LLC
- Site address
- KEY ROAD
- City
- KEENE
- State
- NH
- ZIP
- 03431
- Mailing
- 17 RICHMOND AVE, NEW BRITAIN, CT 06053
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
11 citations on file for this inspection.
1926.150 A01
- Issued
- Jul 20, 2020
- Penalty
- Initial $2,892 · Current $0 Reduced
General-duty citation text
29 CFR 1926.150(a)(1): The employer did not develop and maintain a fire protection program to be followed throughout all phases of construction and demolition work, and/or did not provide for the firefighting equiment as specified in this subpart: Jobsite - No fire extinguishers were supplied near the kerosene gas heaters in the enclosed scaffolding.
Recent events (3)
- — F (S) $0
- — C (S) $2892
- — Z (S) $2892
1926.154 B04
- Issued
- Jul 20, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.154(b)(4): Heaters used in the vicinity of combustible tarpaulins, canvas or similar coverings were not located at least 10 feet from the coverings: Scaffolding - The scaffolding was enclosed with flammable tarps with gas fired heaters on the scaffolding.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.451 A01
- Issued
- Jul 20, 2020
- Penalty
- Initial $4,048 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(a)(1): Each scaffold and scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it. Scaffolding - The wooden scaffolding planks were not capable of supporting four times the load as they were rotten.
Recent events (3)
- — F (S) $0
- — C (S) $4048
- — Z (S) $4048
1926.451 A02
- Issued
- Jul 20, 2020
- Penalty
- Initial $4,048 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(a)(2): Direct connections to roofs and floors, and counterweights used to balance adjustable suspension scaffolds were not capable of resisting at least 4 times the tipping moment imposed by the scaffold operating at the rated load of the Scaffolding - The scaffolding collapsed as the tie-in points were not connected to a structural member.
Recent events (3)
- — F (S) $0
- — C (S) $4048
- — Z (S) $4048
1926.451 E01
- Issued
- Jul 20, 2020
- Penalty
- Initial $4,048 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: Scaffolding - No ladder was supplied for the six tier high scaffolding.
Recent events (3)
- — F (S) $0
- — C (S) $4048
- — Z (S) $4048
1926.451 F03
- Issued
- Jul 20, 2020
- Penalty
- Initial $4,048 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffold and scaffold components were not inspected for visible defects by a competent person before each workshift and after any occurrence which could affect a scaffold's structural integrity: Jobsite - The Tubular Welded Scaffolding was not inspected by a competent person prior to use.
Recent events (3)
- — F (S) $0
- — C (S) $4048
- — Z (S) $4048
1926.451 F07
- Issued
- Jul 20, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. Jobsite - The tubular welded scaffolding was not erected by a competent person.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.451 F12
- Issued
- Jul 20, 2020
- Penalty
- Initial $4,048 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(12): Work on or from scaffolds was not prohibited during storms or high winds and a competent person did not determine that it was safe for employees to be on the scaffold: Jobsite - The Scaffolding collapsed due to high winds as employees worked on the scaffolding.
Recent events (3)
- — F (S) $0
- — C (S) $4048
- — Z (S) $4048
1926.451 G01
- Issued
- Jul 20, 2020
- Penalty
- Initial $4,048 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1m) above a lower level was not protected from falling to that lower level by fall protection established in accordance with paragraphs (g)(1)(i) through (vii) of this section: Scaffolding - Employees were exposed to a fall hazard of up to thirty eight feet while working on the tubular welded scaffolding without fall protection.
Recent events (3)
- — F (S) $0
- — C (S) $4048
- — Z (S) $4048
1926.452 C04
- Issued
- Jul 20, 2020
- Penalty
- Initial $4,048 · Current $0 Reduced
General-duty citation text
29 CFR 1926.452(c)(4): Where uplift could occur which would displace scaffold end frames or panels, the frames or panels were not locked together vertically by pins or equivalent means: Scaffolding - The tubular welded scaffolding frames were not pinned together.
Recent events (3)
- — F (S) $0
- — C (S) $4048
- — Z (S) $4048
1926.454 A
- Issued
- Jul 20, 2020
- Abate by
- Jul 24, 2020
- Penalty
- Initial $4,048 · Current $0 Reduced
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: Jobsite - Employees working from a tubular welded scaffold system were not trained in the recognition and avoidance of hazards associated with tubular welded scaffold usage.
Recent events (3)
- — F (S) $0
- — C (S) $4048
- — Z (S) $4048
More inspections in this industry (NAICS 238140)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344640594.