Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNION POWER STUCCO LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of UNION POWER STUCCO LLC in KEY ROAD, KEENE, NH 03431 (NAICS 238140). OSHA activity number 344640594.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Union Power Stucco LLC — free Get an email when a new federal OSHA severe-injury report for Union Power Stucco LLC is published. One employer, no account, unsubscribe in one click.
Site address
KEY ROAD
City
KEENE
State
NH
ZIP
03431
Mailing
17 RICHMOND AVE, NEW BRITAIN, CT 06053
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

11 citations on file for this inspection.

1926.150 A01

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 20, 2020
Penalty
Initial $2,892 · Current $0 Reduced
29 CFR 1926.150(a)(1): The employer did not develop and maintain a fire protection program to be followed throughout all phases of construction and demolition work, and/or did not provide for the firefighting equiment as specified in this subpart:  Jobsite - No fire extinguishers were supplied near the kerosene gas heaters in the enclosed scaffolding.
Recent events (3)
  • — F (S) $0
  • — C (S) $2892
  • — Z (S) $2892

1926.154 B04

Serious Gravity 10 1 instance 6 exposed
Issued
Jul 20, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.154(b)(4): Heaters used in the vicinity of combustible tarpaulins, canvas or similar coverings were not located at least 10 feet from the coverings:  Scaffolding - The scaffolding was enclosed with flammable tarps with gas fired heaters on the scaffolding.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.451 A01

Serious Gravity 10 1 instance 6 exposed
Issued
Jul 20, 2020
Penalty
Initial $4,048 · Current $0 Reduced
29 CFR 1926.451(a)(1): Each scaffold and scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.  Scaffolding - The wooden scaffolding planks were not capable of supporting four times the load as they were rotten.
Recent events (3)
  • — F (S) $0
  • — C (S) $4048
  • — Z (S) $4048

1926.451 A02

Serious Gravity 10 1 instance 6 exposed
Issued
Jul 20, 2020
Penalty
Initial $4,048 · Current $0 Reduced
29 CFR 1926.451(a)(2): Direct connections to roofs and floors, and counterweights used to balance adjustable suspension scaffolds were not capable of resisting at least 4 times the tipping moment imposed by the scaffold operating at the rated load of the  Scaffolding - The scaffolding collapsed as the tie-in points were not connected to a structural member.
Recent events (3)
  • — F (S) $0
  • — C (S) $4048
  • — Z (S) $4048

1926.451 E01

Serious Gravity 10 1 instance 6 exposed
Issued
Jul 20, 2020
Penalty
Initial $4,048 · Current $0 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:  Scaffolding - No ladder was supplied for the six tier high scaffolding.
Recent events (3)
  • — F (S) $0
  • — C (S) $4048
  • — Z (S) $4048

1926.451 F03

Serious Gravity 10 1 instance 6 exposed
Issued
Jul 20, 2020
Penalty
Initial $4,048 · Current $0 Reduced
29 CFR 1926.451(f)(3): Scaffold and scaffold components were not inspected for visible defects by a competent person before each workshift and after any occurrence which could affect a scaffold's structural integrity:  Jobsite - The Tubular Welded Scaffolding was not inspected by a competent person prior to use.
Recent events (3)
  • — F (S) $0
  • — C (S) $4048
  • — Z (S) $4048

1926.451 F07

Serious Gravity 10 1 instance 6 exposed
Issued
Jul 20, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.   Jobsite - The tubular welded scaffolding was not erected by a competent person.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.451 F12

Serious Gravity 10 1 instance 6 exposed
Issued
Jul 20, 2020
Penalty
Initial $4,048 · Current $0 Reduced
29 CFR 1926.451(f)(12): Work on or from scaffolds was not prohibited during storms or high winds and a competent person did not determine that it was safe for employees to be on the scaffold:  Jobsite - The Scaffolding collapsed due to high winds as employees worked on the scaffolding.
Recent events (3)
  • — F (S) $0
  • — C (S) $4048
  • — Z (S) $4048

1926.451 G01

Serious Gravity 10 1 instance 6 exposed
Issued
Jul 20, 2020
Penalty
Initial $4,048 · Current $0 Reduced
29 CFR 1926.451(g)(1): 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1m) above a lower level was not protected from falling to that lower level by fall protection established in accordance with paragraphs (g)(1)(i) through (vii) of this section:  Scaffolding - Employees were exposed to a fall hazard of up to thirty eight feet while working on the tubular welded scaffolding without fall protection.
Recent events (3)
  • — F (S) $0
  • — C (S) $4048
  • — Z (S) $4048

1926.452 C04

Serious Gravity 10 1 instance 6 exposed
Issued
Jul 20, 2020
Penalty
Initial $4,048 · Current $0 Reduced
29 CFR 1926.452(c)(4): Where uplift could occur which would displace scaffold end frames or panels, the frames or panels were not locked together vertically by pins or equivalent means:  Scaffolding - The tubular welded scaffolding frames were not pinned together.
Recent events (3)
  • — F (S) $0
  • — C (S) $4048
  • — Z (S) $4048

1926.454 A

Serious Gravity 10 1 instance 6 exposed
Issued
Jul 20, 2020
Abate by
Jul 24, 2020
Penalty
Initial $4,048 · Current $0 Reduced
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:  Jobsite -  Employees working from a tubular welded scaffold system were not trained in the recognition and avoidance of hazards associated with tubular welded scaffold usage.
Recent events (3)
  • — F (S) $0
  • — C (S) $4048
  • — Z (S) $4048