Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: LJ&M CONSTRUCTION CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LJ&M CONSTRUCTION CORP. in 31 S. 8TH AVE., MOUNT VERNON, NY 10550 (NAICS 238170). OSHA activity number 344641295.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch LJ&M Construction Corp. for free Get an email when a new federal OSHA severe-injury report for LJ&M Construction Corp. is published. One employer, no account, unsubscribe in one click.
Site address
31 S. 8TH AVE.
City
MOUNT VERNON
State
NY
ZIP
10550
Mailing
138-08 95TH AVE., JAMAICA, NY 11435
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
9
Ownership type
A

6 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 3 instances 6 exposed
Issued
Mar 2, 2020
Penalty
Initial $3,856 · Current $2,417 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access:    location: front of building  on or about: 2/20/20    a) Employees were installing siding from pump jack scaffolds. The employees were not provided with adequate access. The employees were using the hand cranks to raise and lower the scaffold.    NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
  • · I (S) $2417
  • · Z (S) $3856

1926.451 G01 VII

Serious Gravity 10 3 instances 6 exposed
Issued
Mar 2, 2020
Penalty
Initial $5,398 · Current $3,374 Reduced
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    location: exterior of house  on or about: 2/20/20    a) Employees, installing siding from pump jack scaffolds, were not provided without fall protection. The employees were exposed to a fall of up to 19 feet.      NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
  • · I (S) $3374
  • · Z (S) $5398

1926.452 J02

Serious Gravity 1 3 instances 6 exposed
Issued
Mar 2, 2020
Penalty
Initial $2,313 · Current $1,445 Reduced
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.     location: exterior of house  on or about: 2/20/20    a) Employees were working from pump jack scaffolds. The pump jack scaffolds were not bracecd at the bottom of the poles.      NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
  • · I (S) $1445
  • · Z (S) $2313

1926.1053 B01

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 2, 2020
Penalty
Initial $2,313 · Current $1,445 Reduced
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access.     location: side of house  on or about: 2/20/20    a) Employees were using a Werner extension ladder to access a pump jack scaffold. The ladder did not extend 3 ft. above the landing.      NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
  • · I (S) $1445
  • · Z (S) $2313

1926.1053 B04

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 2, 2020
Penalty
Initial $2,313 · Current $1,445 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for the purposes other than the purpose for which they were designed:      location: side of house  on or about: 2/20/20    a) Employees were using a Werner extension ladder, while engaged in exterior siding work. The lanyard, connecting the 2 flys of ladder, was missing.       NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
  • · I (S) $1445
  • · Z (S) $2313

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 2, 2020
Penalty
Initial $5,398 · Current $3,374 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    Location: roof  On or about: 2/20/20    a) Employees were working on the roof, while engaged in exterior siding work. The employees, who was not provided with fall protection, were exposed to a fall of 24 feet.       NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
  • · I (S) $3374
  • · Z (S) $5398