CHICAGO, IL —
OSHA Inspection: LA RONE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LA RONE, INC. in 5004 W. SCHOOL ST., CHICAGO, IL 60641 (NAICS 238160). OSHA activity number 344649363.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LA RONE, INC.
- Site address
- 5004 W. SCHOOL ST.
- City
- CHICAGO
- State
- IL
- ZIP
- 60641
- Mailing
- 386 S. WOODSIDE DRIVE, WOOD DALE, IL 60191
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
19 citations on file for this inspection.
1926.20 B02
- Issued
- Apr 13, 2020
- Abate by
- May 14, 2020
- Penalty
- Initial $4,048 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer safety and health program did not provide for frequent and regular inspections of job sites, materials, and equipment to be made by a competent person(s) designated by the employer: a) On February 24, 2020, the employer did not ensure that it provided for frequent and regular inspections of the job site, materials and equipment by a competent person.
Recent events (2)
- — I (S) $2000
- — Z (S) $4048
1926.102 A01
- Issued
- Apr 13, 2020
- Abate by
- Apr 17, 2020
- Penalty
- Initial $2,892 · Current $1,446 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment was not used when machines or operations presented potential eye or face injury: a) On February 24, 2020 employees without protective eye equipment were exposed to struck-by hazards while using pneumatic nail guns to perform residential roofing work.
Recent events (2)
- — I (S) $1446
- — Z (S) $2892
1926.150 A01
- Issued
- Apr 13, 2020
- Abate by
- Apr 17, 2020
- Penalty
- Initial $3,470 · Current $1,565 Reduced
General-duty citation text
29 CFR 1926.150(a)(1): The employer did not develop and maintain a fire protection program to be followed throughout all phases of construction and demolition work, and/or did not provide for the firefighting equipment as specified in this subpart: a) On February 24, 2020, the employer did not develop and implement a fire prevention and protection program during all phases of construction and demolition work, thereby exposing employees to fire hazards.
Recent events (2)
- — I (S) $1565
- — Z (S) $3470
1926.150 C01 IV
- Issued
- Apr 13, 2020
- Abate by
- Apr 17, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.150(c)(1)(iv): One or more fire extinguishers, rated not less than 2A, were not provided on each floor: a) On February 24, 2020, the employer did not provide fire extinguishers during construction activity at the worksite, thereby exposing employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.403 D01
- Issued
- Apr 13, 2020
- Abate by
- Apr 17, 2020
- Penalty
- Initial $4,048 · Current $1,980 Reduced
General-duty citation text
29 CFR 1926.403(d)(1): Electric equipment was not firmly secured to the surface on which it was mounted: a) On February 24, 2020, an employee was exposed to electric shock hazards where an outlet was not secured or mounted.
Recent events (2)
- — I (S) $1980
- — Z (S) $4048
1926.403 I02 I
- Issued
- Apr 13, 2020
- Abate by
- Apr 17, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(i)(2)(i): Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures: a) On February 24, 2020, wiring used to supply 120-volt power throughout the building was not protected against accidental contact , thereby exposing employees to electric shock hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 B01
- Issued
- Apr 13, 2020
- Abate by
- Apr 17, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(b)(1): Conductors entering boxes, cabinets, or fittings were not protected from abrasion. Openings through which conductors enter were not effectively closed: a) On February 24, 2020, a 120-volt conductor entering an electrical panel was not protected from abrasion and the opening through which the conductor was entering was not effectively closed, thereby exposing an employee to electric shock hazards. b) On February 24, 2020, a 120-volt conductor entering an electrical box on the first floor was not protected from abrasion and the opening through which the conductor was entering was not effectively closed, thereby exposing employees to electric shock hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 B02
- Issued
- Apr 13, 2020
- Abate by
- Apr 17, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(b)(2): All pull boxes, junction boxes, outlet boxes, and fittings were not provided with covers: a) On February 24, 2020, an electrical panel located in the basement did not have a cover installed, thereby exposing an employee to electric shock hazards. b) On February 24, 2020, an employee was exposed to electric shock hazards while using an outlet receptacle in the basement that was not attached to an outlet box and did not have a faceplate. c) On February 24, 2020, an employee was exposed to electric shock hazards while using an outlet receptacle in the attic that did not have a faceplate. d) On February 24, 2020, employees were exposed to electric shock hazards while using an outlet receptacle on the first floor that did not have a faceplate.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.416 A01
- Issued
- Apr 13, 2020
- Abate by
- Apr 17, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: a) On February 24, 2020, employees were exposed to electric shock hazards where work was conducted adjacent to unguarded energized 120-volt electric circuits throughout the building.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.404 B01 II
- Issued
- Apr 13, 2020
- Abate by
- Apr 17, 2020
- Penalty
- Initial $2,892 · Current $1,446 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) On February 24, 2020, an employee was provided with tools and equipment connected by temporary extension cords without the use of an assured equipment grounding program or ground fault circuit interrupters (GFCI), thereby exposing the employee to electric shock hazards.
Recent events (2)
- — I (S) $1446
- — Z (S) $2892
1926.404 E01
- Issued
- Apr 13, 2020
- Abate by
- Apr 17, 2020
- Penalty
- Initial $2,313 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(e)(1)(i): Conductors and equipment rated 600 volts, nominal, or less were not protected from overcurrent in accordance with their ability to safely conduct current: a) On February 24, 2020, employees were exposed to fire hazards where a 120-volt electric circuit providing power to the attic work area was not protected by a circuit breaker.
Recent events (2)
- — I (S) $0
- — Z (S) $2313
1926.405 G02 III
- Issued
- Apr 13, 2020
- Abate by
- Apr 17, 2020
- Penalty
- Initial $2,892 · Current $1,450 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splices or taps: a) On February 24, 2020, employees were exposed to electric shock and fire hazards where flexible cords were spliced together and not protected.
Recent events (2)
- — I (S) $1450
- — Z (S) $2892
1926.416 E01
- Issued
- Apr 13, 2020
- Abate by
- Apr 17, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) On February 24, 2020, worn and damaged extension cords were used to supply electricity to tools and equipment at the site, thereby exposing an employee to electric shock and fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Apr 13, 2020
- Abate by
- Apr 17, 2020
- Penalty
- Initial $2,892 · Current $1,446 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): Safe access was not provided to scaffold platforms that were more than 2 feet above or below the point of access: a) On February 24, 2020, an employee was exposed to the hazard of falling up to approximately fourteen (14) feet where safe access was not provided to ladder jack scaffolding.
Recent events (2)
- — I (S) $1446
- — Z (S) $2892
1926.451 G01 I
- Issued
- Apr 13, 2020
- Abate by
- Apr 17, 2020
- Penalty
- Initial $2,892 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On February 24, 2020, an employee was exposed to the hazard of falling greater than fourteen (14) feet from a ladder jack scaffold and was not protected by a personal fall arrest system.
Recent events (2)
- — I (S) $0
- — Z (S) $2892
1926.454 A
- Issued
- Apr 13, 2020
- Abate by
- May 14, 2020
- Penalty
- Initial $2,892 · Current $1,446 Reduced
General-duty citation text
29 CFR 1926.454(a): Employee(s) performing work while on scaffolds were not trained by a qualified person to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) On February 24, 2020, the employer did not ensure that each employee was provided with training in the recognition and control of the hazards associated with working from ladder jack scaffolding provided for employee use, thereby exposing an employee to fall hazards greater than fourteen (14) feet.
Recent events (2)
- — I (S) $1446
- — Z (S) $2892
1926.503 A01
- Issued
- Apr 13, 2020
- Abate by
- May 14, 2020
- Penalty
- Initial $2,892 · Current $0 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards, to enable each employee to recognize fall hazards and the procedures to be followed in order to minimize these hazards: a) On February 24, 2020 an employee was exposed to the hazard of falling greater than twenty-one (21) feet while performing residential roofing work and the employer did not provide a training program to recognize fall hazards and the procedures to be followed in order to minimize these hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $2892
1926.501 B13
- Issued
- Apr 13, 2020
- Abate by
- Apr 17, 2020
- Penalty
- Initial $2,892 · Current $1,446 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) On February 24, 2020, an employee was performing residential roofing work without fall protection, exposing the employee to fall hazards greater than twenty-one (21) feet.
Recent events (2)
- — I (S) $1446
- — Z (S) $2892
1926.1053 B16
- Issued
- Apr 13, 2020
- Abate by
- Apr 17, 2020
- Penalty
- Initial $2,313 · Current $1,275 Reduced
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: a) On February 24, 2020, an employee was exposed to the hazard of falling approximately five (5) feet when using an extension ladder with structural defects, including a damaged rung on the fly section, to access the ladder jack platform.
Recent events (2)
- — I (S) $1275
- — Z (S) $2313
More inspections at LA Rone, INC.
View LA Rone, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344649363.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.