WEYAUWEGA, WI ·
OSHA Inspection: WELTER FOREST PRODUCTS
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of WELTER FOREST PRODUCTS in 949 LAKEVIEW LANE, WEYAUWEGA, WI 54983 (NAICS 321912). OSHA activity number 344650965.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WELTER FOREST PRODUCTS
- Site address
- 949 LAKEVIEW LANE
- City
- WEYAUWEGA
- State
- WI
- ZIP
- 54983
- Mailing
- P.O. BOX 320, NEW LONDON, WI 54961
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321912
- Employees
- 10
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.101 B
- Issued
- May 1, 2020
- Penalty
- Initial $8,675 · Current $2,000 Reduced
X100
General-duty citation text
29 CFR 1910.101(b): "Compressed gases." The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in Sec. 1910.6. On or about February 25, 2020, the employer did not ensure that all compressed gases in cylinders were stored in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in Sec. 1910.6. A cylinder of oxygen by the southeast man door was not secured to prevent it from falling or being knocked over.
Recent events (2)
- · I (O) $2000
- · Z (S) $8675
1910.253 B04 III
- Issued
- May 1, 2020
- Abate by
- Jun 1, 2020
- Penalty
- Initial $0 · Current $0
0070X100
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. On or about March 11, the employer did not separate oxygen cylinders from acetylene cylinders by a minimum of 20 feet or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. Two oxygen cylinders were stored next to three acetylene cylinders at the north end of the sawmill.
Recent events (2)
- · I (O) $0
- · Z (S) $0
1910.132 D02
- Issued
- May 1, 2020
- Abate by
- Jun 1, 2020
- Penalty
- Initial $0 · Current $0
8110
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: On or about February 25, 2020, the employer did not verify that a workplace hazard assessment had been performed. The employer had assessed the workplace and determined that steel toed shoes, hearing protection, eye protection, and gloves were necessary for the safety of employees, but could not provide a written certification of the assessment.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.134 C02 I
- Issued
- May 1, 2020
- Abate by
- Jun 1, 2020
- Penalty
- Initial $0 · Current $0
9210
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: On or about February 25, 2020, the employer did not provide the information contained in Appendix D to 29 CFR 1910.134 to employees using a respirator voluntarily. Employees wear filtering facepiece respirators when exposed to dusty conditions during the production of hardwood lumber.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Welter Forest Products
View Welter Forest Products's full OSHA safety record →
More inspections in this industry (NAICS 321912)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344650965.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.