Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BROADWIND INDUSTRIAL FABRICATIONS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BROADWIND INDUSTRIAL FABRICATIONS in 300 S 16TH STREET, MANITOWOC, WI 54220 (NAICS 332313). OSHA activity number 344652037.

Watch Broadwind Industrial Fabrications — free Get an email when a new federal OSHA severe-injury report for Broadwind Industrial Fabrications is published. One employer, no account, unsubscribe in one click.
Site address
300 S 16TH STREET
City
MANITOWOC
State
WI
ZIP
54220
Mailing
101 S 16TH STREET, MANITOWOC, WI 54220
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332313
Employees
42
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 15 instances 4 exposed
Issued
Abate by
Penalty
Initial $6554.00 · Current $4588.00 Reduced
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:    On or about February 25, 2020 the employer failed to clearly identify all of the specific steps to be followed by employees to isolate and disable the equipment in the Industrial Fabrications in order to safely de-energize the equipment and control the energy hazards and to prevent unintentional exposure to hazardous energy. The current procedures lacked the following:      1. The purpose, scope and authorization of the energy control procedure(s);  2. Identify the steps to take in order to ensure residual and/or stored energy has been removed; and  3. Specific steps to verify and test that de-energization and isolation has been accomplished.
Recent events (2)
  • — I (S) $4587.8
  • — Z (S) $6554

1910.147 C06 I

Serious Gravity 5 15 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed:   On or about February 25, 2020 the employer had not conducted periodic inspections of their lockout procedures within the previous 12 months.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344652037.