Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RANGER FIRE, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RANGER FIRE, INC. in ORLEANS AT FANNIN STATION 1818 FANNIN SPEEDWAY, HOUSTON, TX 77045 (NAICS 238220). OSHA activity number 344652193.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ranger Fire, INC. — free Get an email when a new federal OSHA severe-injury report for Ranger Fire, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
RANGER FIRE, INC.
Site address
ORLEANS AT FANNIN STATION 1818 FANNIN SPEEDWAY
City
HOUSTON
State
TX
ZIP
77045
Mailing
1000 S. MAIN STREET SUITE 150, GRAPEVINE, TX 76051
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
8
Ownership type
A

3 citations on file for this inspection.

1926.150 C01 I

Other-than-serious 10 instances 8 exposed
Issued
Mar 13, 2020
Abate by
Mar 19, 2020
Penalty
Initial $5,407 · Current $2,791 Reduced
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof:    a)  At the construction site, Building B, where no fire extinguishers were available on the third floor.
Recent events (2)
  • — I (O) $2791
  • — Z (S) $5407

1926.501 B01

Other-than-serious 1 instance 8 exposed
Issued
Mar 13, 2020
Penalty
Initial $9,012 · Current $5,399 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:    a)  On the third floor of Building B, where an elevator shaft was not guarded, exposing employees to a fall hazard of approximately 18 feet.
Recent events (2)
  • — I (O) $5399
  • — Z (S) $9012

1904.39 A02

Repeat 1 instance 1 exposed
Issued
Mar 13, 2020
Penalty
Initial $53,015 · Current $31,809 Reduced
29 CFR 1904.39(a)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye:    a)  At the construction site, a hospitalization occurring on January 20, 2020 was not reported to OSHA until January 22, 2020.    RANGER FIRE, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, 29 CFR 1904.39(a)(2), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1410933, CITATION NUMBER 2, ITEM NUMBER1 AND BECAME FINAL ORDER ON NOVEMBER 12, 2016 WITH RESPECT TO A WORKPLACE LOCATED AT FCI EL RENO, EL RENO, OKLAHOMA.
Recent events (2)
  • — I (R) $31809
  • — Z (R) $53015

View Ranger Fire, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344652193.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.