UTICA, NY —
OSHA Inspection: NATIONAL BUILDING RESTORATION CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NATIONAL BUILDING RESTORATION CORPORATION in 116 BUSINESS PARK DRIVE, UTICA, NY 13502 (NAICS 236220). OSHA activity number 344660576.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL BUILDING RESTORATION CORPORATION
- Site address
- 116 BUSINESS PARK DRIVE
- City
- UTICA
- State
- NY
- ZIP
- 13502
- Mailing
- 1010 TILDEN AVE, UTICA, NY 13501
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 20
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.304 F
- Issued
- Jun 4, 2020
- Abate by
- Jun 15, 2020
- Penalty
- Initial $3,856 · Current $3,856
General-duty citation text
29 CFR 1926.304(f) Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: 29 CFR 1926.304(f) Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: 29 CFR 1926.304(f) Section 5.1.3.3 American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure: a) Northwest corner of building, ground floor, on or about 2-28-20: One employee was ripping plywood using a table saw that was not equipped with a spreader. b) Northwest corner of building, ground floor, on or about 2-28-20: One employee was ripping plywood using a table saw that was not equipped with non kick-back fingers or "dogs". c) Northwest corner of building, ground floor, on or about 2-28-20: One employee was ripping plywood using a table saw that was not equipped with a magnetic switch or anti-restart device. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (3)
- — J (S) $3856
- — C (S) $3856
- — Z (S) $3856
1926.304 I01
- Issued
- Jun 4, 2020
- Abate by
- Jun 15, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: a) Northwest corner of building, ground floor, on or about 2-28-20: One employee was ripping plywood using a table saw that was not equipped a hood guard that automatically adjusts to enclose the saw blade. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.404 B01 II
- Issued
- Jun 4, 2020
- Penalty
- Initial $3,084 · Current $3,084
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) Northwest corner of building, ground floor, on or about 2-28-20: Employees were using various power tools, powered through receptacles that were not protected by ground fault circuit interrupters (GFCI).
Recent events (3)
- — J (S) $3084
- — C (S) $3084
- — Z (S) $3084
1926.416 E01
- Issued
- Jun 4, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) Northwest corner of building, ground floor, on or about 2-28-20: Employees were using various power tools, powered through two separate 3-way cords that exhibited damage.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at National Building Restoration Corporation
View National Building Restoration Corporation's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344660576.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.