OSHA Inspection: NATIONAL BUILDING RESTORATION CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NATIONAL BUILDING RESTORATION CORPORATION in 116 BUSINESS PARK DRIVE, UTICA, NY 13502 (NAICS 236220). OSHA activity number 344660576.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Building Restoration Corporation — free Get an email when a new federal OSHA severe-injury report for National Building Restoration Corporation is published. One employer, no account, unsubscribe in one click.
Site address
116 BUSINESS PARK DRIVE
City
UTICA
State
NY
ZIP
13502
Mailing
1010 TILDEN AVE, UTICA, NY 13501
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
20
Ownership type
A

4 citations on file for this inspection.

1926.304 F

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 4, 2020
Abate by
Jun 15, 2020
Penalty
Initial $3,856 · Current $3,856
29 CFR 1926.304(f)  Section 4.1.2(b)  American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator:           29 CFR 1926.304(f)  Section 4.1.2(c)  American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:           29 CFR 1926.304(f)  Section 5.1.3.3  American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure:            a) Northwest corner of building, ground floor, on or about 2-28-20:  One employee was ripping plywood using a table saw that was not equipped with a spreader.     b) Northwest corner of building, ground floor, on or about 2-28-20:  One employee was ripping plywood using a table saw that was not equipped with non kick-back fingers or "dogs".     c) Northwest corner of building, ground floor, on or about 2-28-20:  One employee was ripping plywood using a table saw that was not equipped with a magnetic switch or anti-restart device.   ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (3)
  • — J (S) $3856
  • — C (S) $3856
  • — Z (S) $3856

1926.304 I01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 4, 2020
Abate by
Jun 15, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut:    a) Northwest corner of building, ground floor, on or about 2-28-20:  One employee was ripping plywood using a table saw that was not equipped a hood guard that automatically adjusts to enclose the saw blade.   ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.404 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 4, 2020
Penalty
Initial $3,084 · Current $3,084
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:   a) Northwest corner of building, ground floor, on or about 2-28-20:  Employees were using various power tools, powered through receptacles that were not protected by ground fault circuit interrupters (GFCI).
Recent events (3)
  • — J (S) $3084
  • — C (S) $3084
  • — Z (S) $3084

1926.416 E01

Serious Gravity 5 2 instances 1 exposed
Issued
Jun 4, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:    a) Northwest corner of building, ground floor, on or about 2-28-20:  Employees were using various power tools, powered through two separate 3-way cords that exhibited damage.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

View National Building Restoration Corporation's full OSHA safety record →