Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACCURATE WELDING SERVICES, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ACCURATE WELDING SERVICES, LLC in 7 INDUSTRIAL ROAD, WINDSOR LOCKS, CT 06096 (NAICS 332322). OSHA activity number 344666292.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Accurate Welding Services, LLC — free Get an email when a new federal OSHA severe-injury report for Accurate Welding Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
7 INDUSTRIAL ROAD
City
WINDSOR LOCKS
State
CT
ZIP
06096
Mailing
7 INDUSTRIAL ROAD, WINDSOR LOCKS, CT 06096
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
5
Ownership type
A

1 citation on file for this inspection.

1910.178 P01

Other-than-serious 1 instance 2 exposed
Issued
Jun 19, 2020
Abate by
Aug 6, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition:    a. Shop area: the Hyster forklift was found to be emitting carbon monoxide as high as 1524 ppm when Drager PAC 7000 CO detector was held approximately three to four feet away from the exhaust while it was running, exposing employees to potential carbon monoxide poisoning.    b. Shop area: the Hyster forklift was found to have an inoperable horn.  c. Shop area: the Big Joe electric pallet jack, Model # POM 30-10, Serial # 313668,  was found to have an inoperable horn.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344666292.