Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ECUA CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ECUA CONSTRUCTION in 3 NEIL ROAD, SPRING VALLEY, NY 10977 (NAICS 238170). OSHA activity number 344666300.

Watch Ecua Construction — free Get an email when a new federal OSHA severe-injury report for Ecua Construction is published. One employer, no account, unsubscribe in one click.
Establishment
ECUA CONSTRUCTION
Site address
3 NEIL ROAD
City
SPRING VALLEY
State
NY
ZIP
10977
Mailing
55-55 GIAFTON AVENUE, NEWARK, NJ 07104
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
6
Ownership type
A

5 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $1735.00 · Current $1735.00
29 CFR 1926.100(a):   Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:   A) Exterior on the ground: Employees were exposed to head injuries while working below roofing/siding activities. The employee were not protected by hard hats or protective helmets, on or about March 2nd, 2020.   NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $1735

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $4048.00 · Current $4048.00
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level.   A) Exterior, Pump jack scaffold on the left side of the structure: Employees were exposed to fall hazards of approximately 22 feet while working on a pump jack scaffold that was not protected by a complete guardrail system (including end rails) or another means of fall protection in place, on or about March 2nd, 2020.   NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $4048

1926.452 J02

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $4048.00 · Current $4048.00
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.   A) Exterior, Pump jack scaffold in the front of the structure: Employees were exposed to fall hazards of approximately 22 feet while working on a pump jack scaffold that was not braced at the bottom, on or about March 2nd, 2020.   NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $4048

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $4048.00 · Current $4048.00
29 CFR 1926.501(b)(13):   Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    A) Roof of the structure: Two employees were exposed to fall hazards of approximately 32 feet while engaged in roofing/siding work on the roof of a house without a means of fall protection in place, on or about March 2nd, 2020.   NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $4048

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $4048.00 · Current $4048.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    A) Exterior, Up top the scaffold: Employees were exposed to fall hazards of approximately 22 feet while using an extension ladder that was not extended at least 3 feet over the landing that they were accessing, on or about March 2nd, 2020.   NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $4048

View ECUA CONSTRUCTION's full OSHA safety record →