PASADENA, TX ·
OSHA Inspection: PCI NITROGEN, LLC
Fatality or catastrophe inspection · Safety discipline
At a glance
On , OSHA opened a fatality or catastrophe safety inspection of PCI NITROGEN, LLC in 2001 JACKSON RD., PASADENA, TX 77506 (NAICS 325311). OSHA activity number 344666961.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PCI NITROGEN, LLC
- Site address
- 2001 JACKSON RD.
- City
- PASADENA
- State
- TX
- ZIP
- 77506
- Mailing
- 2001 JACKSON RD., PASADENA, TX 77506
What kind of inspection was it?
- Inspection type
- Fatality or catastrophe (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325311
- Employees
- 126
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.28 B01 I
- Issued
- May 27, 2020
- Abate by
- Jul 1, 2020
- Penalty
- Initial $12,145 · Current $12,145
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one of the methods listed in paragraphs 1910.28(b)(1)(i)(A) - (b)(1)(i)(C): a) On February 28, 2020, and times prior to, where the employer did not ensure that employees were protected from falls while making adjustments on the single line and double line brakes from the trolley platform of overhead crane 995 in Building 9.
Recent events (1)
- · Z (S) $12145
1910.147 C04 I
- Issued
- May 27, 2020
- Abate by
- Jul 1, 2020
- Penalty
- Initial $12,145 · Current $12,145
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On February 28, 2020, and times prior to, where the employer did not ensure that a hazardous energy control procedure was utilized when electrical technicians accessed crane 995 to perform maintenance in Building 9.
Recent events (1)
- · Z (S) $12145
1910.147 D04 I
- Issued
- May 27, 2020
- Abate by
- Jul 1, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) On February 28, 2020, and times prior to, where the employer did not ensure that lockout or tagout devices were utilized when electrical technicians accessed crane 995 to perform maintenance in Building 9.
Recent events (1)
- · Z (S) $0
1910.179 L02 I C
- Issued
- May 27, 2020
- Abate by
- Jul 1, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(l)(2)(i)(c): The main or emergency switch was not open and locked in the open position: a) On February 28, 2020, and times prior to, where the main switch on crane 995 was not locked in the open position while maintenance was being performed on the single and double line brakes.
Recent events (1)
- · Z (S) $0
1910.179 B05
- Issued
- May 27, 2020
- Abate by
- Jul 1, 2020
- Penalty
- Initial $12,145 · Current $12,145
General-duty citation text
29 CFR 1910.179(b)(5): The rated load of crane(s) was not plainly marked on each side of the crane: a) On February 28, 2020, and times prior to, where the load rating was not marked overhead crane 995 in Building 9. The crane is used to move fertilizer throughout the building and into hoppers for shipment.
Recent events (1)
- · Z (S) $12145
1910.179 E06 I
- Issued
- May 27, 2020
- Abate by
- Jul 1, 2020
- Penalty
- Initial $12,145 · Current $12,145
General-duty citation text
29 CFR 1910.179(e)(6)(i): Exposed moving part(s) which might constitute a hazard under normal operating conditions were not guarded: a) On February 28, 2020, and times prior to, where the rotating drums for the single line and double line wire ropes were not guarded on the trolley platform of overhead crane 995 in Building 9.
Recent events (1)
- · Z (S) $12145
1910.179 G02 I
- Issued
- May 27, 2020
- Abate by
- Jul 1, 2020
- Penalty
- Initial $10,409 · Current $10,409
General-duty citation text
29 CFR 1910.179(g)(2)(i): Electrical equipment was not so located or enclosed that live parts would not be exposed to accidental contact under normal operating conditions: a) On March 2, 2020, and times prior to, where there was no cover on the junction box in the cab of the overhead crane 995 in Building 9.
Recent events (1)
- · Z (S) $10409
1910.179 L02 I D
- Issued
- May 27, 2020
- Abate by
- Jul 1, 2020
- Penalty
- Initial $10,409 · Current $10,409
General-duty citation text
29 CFR 1910.179(l)(2)(i)(d): Warning or "out of order" signs shall be placed on the crane, also on the floor beneath or on the hook where visible from the floor: a) On February 28, 2020, and times prior to, where there was no "out of order sign" placed on the crane while the maintenance was being performed on the single and double line brakes.
Recent events (1)
- · Z (S) $10409
More inspections in this industry (NAICS 325311)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344666961.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.