Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PURE FLAVOR HOTHOUSE

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of PURE FLAVOR HOTHOUSE in 9610 BALL ST, SAN ANTONIO, TX 78218 (NAICS 311423). OSHA activity number 344669072.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pure Flavor Hothouse — free Get an email when a new federal OSHA severe-injury report for Pure Flavor Hothouse is published. One employer, no account, unsubscribe in one click.
Site address
9610 BALL ST
City
SAN ANTONIO
State
TX
ZIP
78218
Mailing
9610 BALL ST, SAN ANTONIO, TX 78218
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311423
Employees
97
Ownership type
A

4 citations on file for this inspection.

1910.176 A

Serious Gravity 5 2 instances 97 exposed
Issued
Jul 1, 2020
Abate by
Jul 22, 2020
Penalty
Initial $8,675 · Current $5,205 Reduced
29 CFR 1910.176(a): Use of mechanical equipment. Where mechanical handling equipment is used, sufficient safe clearances shall be allowed for aisles, at loading docks, through doorways and wherever turns or passage must be made. Aisles and passageways shall be kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. Permanent aisles and passageways shall be appropriately marked.  Throughout the warehouse:  On or about March, 03 2020, employees were exposed to struck-by hazards, while working near a Crown Electric Forklift without proper aisle and passageway markings.
Recent events (2)
  • — I (S) $5205
  • — Z (S) $8675

1910.219 C04 I

Serious Gravity 5 4 instances 17 exposed
Issued
Jul 1, 2020
Abate by
Jul 22, 2020
Penalty
Initial $6,940 · Current $4,164 Reduced
29 CFR 1910.219(c)(4)(i): Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves.   a.  Production Staging Area, Top Sealer: On or about March, 03 2020, employees were exposed to caught in hazards, while working near unprotected rotating shaft.  b.  Production Staging Area, TX Wrap: On or about March, 03 2020, employees were exposed to caught in hazards, while working near unprotected rotating shaft.  c.  Production Staging Area, Over Wrap:  On or about March, 03 2020, employees were exposed to caught in hazards, while working near unprotected rotating shaft.  d.  Production Staging Area, Line 3:  On or about March, 03 2020, employees were exposed to caught in hazards, while working near unprotected rotating shaft.
Recent events (2)
  • — I (S) $4164
  • — Z (S) $6940

1910.303 B02

Serious Gravity 5 4 instances 17 exposed
Issued
Jul 1, 2020
Abate by
Jul 22, 2020
Penalty
Initial $10,409 · Current $6,245 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listed or labeling:   a.  Production Staging Area, Top Sealer: On or about March, 03 2020,  employees were exposed to electrical hazards, while connecting a scale and portable electrical tools into a quad-box outlet.  b.  Production Staging Area, TX Wrap:  On or about March, 03 2020, employees were exposed to electrical hazards, while connecting a scale and portable electrical tools into a quad-box outlet.  c.  Production Staging Area, Over Wrap: On or about March, 03 2020, employees were exposed to electrical hazards, while connecting a scale and portable electrical tools into a quad-box outlet.  d.  Production Staging Area, Line 3:  On or about March, 03 2020, employees were exposed to electrical hazards, while connecting a scale and portable electrical tools into a quad-box outlet.
Recent events (2)
  • — I (S) $6245.4
  • — Z (S) $10409

1910.305 G01 IV A

Serious Gravity 5 4 instances 17 exposed
Issued
Jul 1, 2020
Abate by
Jul 22, 2020
Penalty
Initial $10,409 · Current $6,245 Reduced
29 CFR 1910.305(g)(1)(iv)(A): As a substitute for the fixed wiring of a structure:   a.  Production Staging Area, Top Sealer: On or about March, 03 2020,  employees were exposed to electrical hazards, while connecting a scale and portable electrical tools into a quad-box outlet not being properly mounted.  b.  Production Staging Area, TX Wrap:  On or about March, 03 2020, employees were exposed to electrical hazards, while connecting a scale and portable electrical tools into a quad-box outlet not being properly mounted.  c.  Production Staging Area, Over Wrap: On or about March, 03 2020, employees were exposed to electrical hazards, while connecting a scale and portable electrical tools into a quad-box outlet not being properly mounted.  d.  Production Staging Area, Line 3:  On or about March, 03 2020, employees were exposed to electrical hazards, while connecting a scale and portable electrical tools into a quad-box outlet not being properly mounted.
Recent events (2)
  • — I (S) $6245.4
  • — Z (S) $10409

View Pure Flavor Hothouse's full OSHA safety record →