LUCK, WI ·
OSHA Inspection: MACDONALD & OWEN VENEER AND LUMBER CO., INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MACDONALD & OWEN VENEER AND LUMBER CO., INC. in 230 SOUTH DUNCAN STREET, LUCK, WI 54853 (NAICS 423310). OSHA activity number 344669262.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MACDONALD & OWEN VENEER AND LUMBER CO., INC.
- Site address
- 230 SOUTH DUNCAN STREET
- City
- LUCK
- State
- WI
- ZIP
- 54853
- Mailing
- 1500 WEST CITY HIGHWAY 16, WEST SALEM, WI 54669
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423310
- Employees
- 32
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.147 C04 II
- Issued
- Mar 30, 2020
- Abate by
- Apr 20, 2020
- Penalty
- Initial $11,450 · Current $6,870 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): (a) 230 South Duncan Street, Luck, WI; At the Cantek surface planer, the employer did not ensure that applicable energy control procedure elements involving the dissipation of residual energy [(d)(5)(i)] and verification of isolation [(d)(6)] were implemented to safeguard employee(s) from the machine servicing hazard(s) associated with the equipment.
Recent events (2)
- · I (S) $6870
- · Z (S) $11450
1910.147 D
- Issued
- Mar 30, 2020
- Abate by
- Apr 20, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) 230 South Duncan Street, Luck, WI; At the Cantek surface planer, on or about December 11, 2019, an employee performing service work was exposed to hazardous energy associated with moving machine parts as residual energy was not relieved or otherwise rendered safe [(d)(5)(i)] and verification of isolation [(d)(6)] was not performed following the application of lockout device(s).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.132 D01
- Issued
- Mar 30, 2020
- Abate by
- Apr 20, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment: (a) 230 South Duncan Street, Luck, WI; The employer did not assess hazards and select adequate personal protective equipment to protect employee(s) from exposure while performing task(s) associated with filling liquefied petroleum gas cylinders.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.138 A
- Issued
- Mar 30, 2020
- Abate by
- Apr 20, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes: (a) 230 South Duncan Street, Luck WI; At the propane filling station, an employee had performed task(s) associated with filling liquefied petroleum gas cylinders without adequate hand protection.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Macdonald & Owen Veneer and Lumber CO., INC.
View Macdonald & Owen Veneer and Lumber CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423310)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344669262.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.