OSHA Inspection: JOHNSON RESEARCH & DEVELOPMENT CO., INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JOHNSON RESEARCH & DEVELOPMENT CO., INC. in 275 DECATUR STREET, ATLANTA, GA 30312 (NAICS 541710). OSHA activity number 344674403.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Johnson Research & Development CO., INC. — free Get an email when a new federal OSHA severe-injury report for Johnson Research & Development CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
275 DECATUR STREET
City
ATLANTA
State
GA
ZIP
30312
Mailing
275 DECATUR STREET, ATLANTA, GA 30312
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541710
Employees
7
Ownership type
A

4 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 4 instances 2 exposed
Issued
Aug 27, 2020
Abate by
Sep 23, 2020
Penalty
Initial $2,892 · Current $1,735 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):   a)     Research Facility, Machine shop:  On or about 3/5/2020, and at times prior, the employer exposed employees to amputation hazards, in that scroll saws were not properly guarded at the point of operation to protect employees while doing cutting operations in the development of prototypes.  b)     Research Facility, Machine shop:  On or about 3/5/2020, and at times prior, the employer exposed employees to amputation hazards, in that mechanical saws were not properly guarded at the point of operation to protect employees while doing cutting operations in the development of prototypes.  c)     Research Facility, Machine shop:  On or about 3/5/2020, and at times prior, the employer exposed employees to amputation hazards, in that drill presses were not properly guarded at the point of operation to protect employees while doing drilling operations in the development of prototypes.  d)     Research Facility, Machine shop:  On or about 3/5/2020, and at times prior, the employer exposed employees to amputation hazards, in that lathes were not properly guarded at the point of operation to protect employees while doing cutting operations in the development of prototypes.
Recent events (2)
  • — I (S) $1735.2
  • — Z (S) $2892

1910.303 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 27, 2020
Abate by
Sep 23, 2020
Penalty
Initial $2,313 · Current $1,388 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a)  Research facility, Small chemical lab:  On or about 3/5/2020, and at times prior, the employer exposed employees to fire and electrical shock hazards, in that they are using power strips as permanent power sources for fans and other equipment while conducting experiments in the lab.
Recent events (2)
  • — I (S) $1387.8
  • — Z (S) $2313

1910.36 G02

Other-than-serious 1 instance 2 exposed
Issued
Aug 27, 2020
Abate by
Sep 23, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.  a) Research facility, Small Lab:  On or about 3/5/2020, and at times prior, the employer exposed employees to fire hazards, in that the doorway leading out of the small lab into the main lab area only had 25 inches of clearance for employees to escape in the event of an emergency. The lab is used to conduct experiments for the development of new inventions.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 2 exposed
Issued
Aug 27, 2020
Abate by
Sep 23, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) Research Facility, Machine Shop back left wall:  On or about 3/5/2020, and at times prior, the employer exposed employees to fire hazards, in that a clear space was not maintained  around the power panel in the machine shop used to turn on equipment and lighting. The shop is used by employees to produce prototypes for new inventions.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Johnson Research & Development CO., INC.'s full OSHA safety record →