Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PROSSER LABORATORIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PROSSER LABORATORIES, INC. in NIGHTINGALE WAY, TANNERSVILLE, PA 18372 (NAICS 541380). OSHA activity number 344675582.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Prosser Laboratories, INC. — free Get an email when a new federal OSHA severe-injury report for Prosser Laboratories, INC. is published. One employer, no account, unsubscribe in one click.
Site address
NIGHTINGALE WAY
City
TANNERSVILLE
State
PA
ZIP
18372
Mailing
PO BOX 118, EFFORT, PA 18330
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541380
Employees
27
Ownership type
A

5 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 1 1 instance 2 exposed
Issued
May 14, 2020
Abate by
Sep 15, 2020
Penalty
Initial $3,036 · Current $1,750 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems:    a) Tannersville, PA: Employees walking on top of waste water tanks, which had an unprotected edge that was more than five (5) feet above the lower level, were not protected from falling, on or about March 5, 2020.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3036

1910.28 B03 I

Serious Gravity 1 1 instance 2 exposed
Issued
May 14, 2020
Abate by
Sep 15, 2020
Penalty
Initial $0 · Current $1,750
29 CFR 1910.28(b)(3)(i): The employer did not ensure each employee is protected from falling through any hole (including skylights) that is 4 feet (1.2 m) or more above a lower level by one or more of the following: covers, guardrail systems, travel restraint systems, or personal fall arrest systems, as required by sub-items A through D of this section:    a) Tannersville, PA: Employees who performed work on open-top waste water tanks were exposed to falling into the tanks, which were approximately 10 feet deep, on or about March 5, 2020.     ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1750
  • — Z (S) $0

1910.28 B11 II

Serious Gravity 1 1 instance 2 exposed
Issued
May 14, 2020
Abate by
Sep 15, 2020
Penalty
Initial $3,036 · Current $1,000 Reduced
29 CFR 1910.28(b)(11)(ii): Each flight of stairs having at least 3 treads and at least 4 risers was not equipped with stair rail systems and handrails as required in Table D-2 of this standard:    a) Tannersville, PA: Stairs leading to the top of a waste water tank, which were constructed with six (6) risers where not equipped with a stair rail on each open side, which exposed employees to a fall, on or about March 5, 2020.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3036

1910.219 D01

Serious Gravity 1 2 instances 2 exposed
Issued
May 14, 2020
Abate by
Jul 1, 2020
Penalty
Initial $3,036 · Current $1,000 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a) Tannersville, PA: Motor driven pulleys used to power pumps in a waste water treatment facility were not enclosed by a guard, which exposed employees to an in-running nip point hazard, on or about March 5, 2020.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3036

1910.219 E01 I

Serious Gravity 1 2 instances 2 exposed
Issued
May 14, 2020
Abate by
Jul 1, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):  a) Tannersville, PA: Motor driven belts used to power a pump in a waste water treatment facility were not enclosed by a guard, which exposed employees to an abrasion hazard, on or about March 5, 2020.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Prosser Laboratories, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344675582.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.