YORK, PA ·
OSHA Inspection: ROOFING WITH INTEGRITY LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ROOFING WITH INTEGRITY LLC in 3208 REX DRIVE, YORK, PA 17402 (NAICS 238160). OSHA activity number 344683453.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROOFING WITH INTEGRITY LLC
- Site address
- 3208 REX DRIVE
- City
- YORK
- State
- PA
- ZIP
- 17402
- Mailing
- 432 PENN STREET, HANOVER, PA 17331
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Mar 16, 2020
- Abate by
- Apr 9, 2020
- Penalty
- Initial $4,048 · Current $3,250 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) 3208 REX DRIVE, YORK, PA - Employees performed roofing operations, the employees were not protected by any means of fall protection, on or about March 5, 2020. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- · I (S) $3250
- · Z (S) $4048
1926.1053 B01
- Issued
- Mar 16, 2020
- Abate by
- Apr 9, 2020
- Penalty
- Initial $4,048 · Current $3,250 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access: (a) 3208 REX DRIVE, YORK, PA - Employees accessed the South end of the Front of the house using a Werner 20 foot extension ladder, and the rungs of the ladder were only approximately eight inches past the upper landing surface, on or about March 5, 2020. (b) 3208 REX DRIVE, YORK, PA - Employees accessed the North end of the rear of the house using an unmarked 40 foot extension ladder, and the rungs of the ladder were only approximately 18 inches past the upper landing surface, on or about March 5, 2020. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- · I (S) $3250
- · Z (S) $4048
1926.1053 B04
- Issued
- Mar 16, 2020
- Abate by
- Apr 9, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were not used for the purpose for which they were designed: (a) 3208 REX DRIVE, YORK PA, REAR OF HOUSE SECOND STORY - Employees accessed the second story roof from the first story roof by using a Werner six foot step-ladder that was in the closed position and leaned against the side of the house, on or about March 5, 2020. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 238160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344683453.