Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THOMAS & GALBRAITH HEATING AND COOLING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of THOMAS & GALBRAITH HEATING AND COOLING, INC. in 10445 SHARONDALE RD., CINCINNATI, OH 45241 (NAICS 238220). OSHA activity number 344689997.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Thomas & Galbraith Heating and Cooling, INC. — free Get an email when a new federal OSHA severe-injury report for Thomas & Galbraith Heating and Cooling, INC. is published. One employer, no account, unsubscribe in one click.
Site address
10445 SHARONDALE RD.
City
CINCINNATI
State
OH
ZIP
45241
Mailing
1077 3RD AVE., CARMEL, IN 46032
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
70
Ownership type
A

5 citations on file for this inspection.

1926.651 C02

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
May 7, 2020
Penalty
Initial $8,501 · Current $0 Reduced
29 CFR 1926.651(c)(2): Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.  On March 11, 2020, located in an excavation on a residential construction site, an employee working inside aluminum hydraulic shoring without a safe means of egress in which an extension ladder located outside the shoring exposing the employee to a cave-in hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8501

1926.652 C02 III

Other-than-serious 1 instance 1 exposed
Issued
May 7, 2020
Penalty
Initial $8,501 · Current $1,500 Reduced
29 CFR 1926.652(c)(2)(iii): Manufacturer's specifications, recommendations, and limitations, and manufacturer's approval to deviate from the specifications, recommendations, and limitations shall be in written form at the jobsite during construction of the protective system. After that time this data may be stored off the jobsite, but a copy shall be made available to the Secretary upon request.    On March 11, 2020, located in an excavation on a residential construction site, a copy of the manufacturer's specification, recommendations, and limitations, and manufacturer's approval to deviate from the specifications, for the Efficiency Production Aluminum Hydraulic Shoring, was not maintained on-site during construction of the protective system and could not be provided to the Secretary at the time of the inspection.
Recent events (2)
  • — I (O) $1500
  • — Z (S) $8501

1926.652 D02

Serious Gravity 10 1 instance 1 exposed
Issued
May 7, 2020
Penalty
Initial $8,501 · Current $5,951 Reduced
29 CFR 1926.652(d)(2): Manufactured materials and equipment used for protective systems shall be used and maintained in a manner that is consistent with the recommendations of the manufacturer, and in a manner that will prevent employee exposure to hazards.    On March 11, 2020, located in an excavation on a residential construction site, an employee working in an excavation 9 in-depth without adequate protection against cave-ins, in that the walls of the excavation were not properly shored per Efficiency Production installation and procedures of the hydraulic shoring system to protect against collapse.
Recent events (2)
  • — I (S) $5950.7
  • — Z (S) $8501

1926.1053 B01

Other-than-serious 1 instance 1 exposed
Issued
May 7, 2020
Penalty
Initial $8,501 · Current $1,500 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.    On March 11, 2020, located in an excavation on a residential construction site, an employee utilized an extension ladder located inside a 9' in-depth excavation that did not extend past the upper landing surface 3', allowing an employee a handrail a safe means of accessing or egressing from the excavation.
Recent events (2)
  • — I (O) $1500
  • — Z (S) $8501

1926.1053 B04

Serious Gravity 10 1 instance 1 exposed
Issued
May 7, 2020
Penalty
Initial $8,501 · Current $0 Reduced
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed.    On March 11, 2020, located in a 9' depth excavation on a residential construction site, an employee utilized an extension ladder that had been separated into two sections to access and egress inside an excavation for which it was not designed for this purpose.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8501

View Thomas & Galbraith Heating and Cooling, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344689997.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.