WESTBROOK, ME ·
OSHA Inspection: YRC FREIGHT
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of YRC FREIGHT in 75 EISENHOWER DRIVE, WESTBROOK, ME 04092 (NAICS 484122). OSHA activity number 344690102.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- YRC FREIGHT
- Site address
- 75 EISENHOWER DRIVE
- City
- WESTBROOK
- State
- ME
- ZIP
- 04092
- Mailing
- 75 EISENHOWER DRIVE, WESTBROOK, ME 04092
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484122
- Employees
- 23
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.157 C01
- Issued
- May 20, 2020
- Penalty
- Initial $4,178 · Current $1,671 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: Warehouse - Three portable fire extinguishers were blocked by various items including carts, metal pieces, cords, and materials.
Recent events (3)
- · F (O) $1671.2
- · C (S) $4178
- · Z (S) $4178
1910.304 G05
- Issued
- May 20, 2020
- Abate by
- May 29, 2020
- Penalty
- Initial $6,553 · Current $6,553
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: In the following instances, the path to ground was not permanent, continuous, and effective: a) Garage Door #1 - The outside extension cord was missing a grounding pin. b) Garage Door #12 - One or more conductors of the electrical cord suppling power to the light was severed.
Recent events (3)
- · F (O) $6553
- · C (S) $6553
- · Z (S) $6553
1910.305 G01 IV A
- Issued
- May 20, 2020
- Abate by
- Jun 2, 2020
- Penalty
- Initial $6,554 · Current $2,622 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Patio Trailer - An extension cord, versus fixed wiring, is being used to supply power to the lights in the trailer.
Recent events (3)
- · F (O) $2621.6
- · C (S) $6554
- · Z (S) $6554
1910.151 C
- Issued
- May 20, 2020
- Abate by
- Jun 9, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: Facility - The eyewash station was not available for immediate use, as it was located in a closet, a good distance from possible exposure.
Recent events (3)
- · F (O) $0
- · C (O) $0
- · Z (O) $0
1910.303 B08 I
- Issued
- May 20, 2020
- Abate by
- May 29, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(8)(i): Electrical equipment was not firmly secured to the surface on which it was mounted: Warehouse - The electrical outlet, located between garage doors #13 and #14, was not firmly secured to the wall on which it was mounted.
Recent events (3)
- · F (O) $0
- · C (O) $0
- · Z (O) $0
1910.305 J02 VI
- Issued
- May 20, 2020
- Abate by
- Jun 2, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(vi): A receptacle installed in a wet location where the product intended to be plugged into it was not to be attended while in use (for example, sprinkler system controllers, landscape lighting, and holiday lights) did not have an enclosure that was weatherproof with the attachment plug cap inserted or removed: Outside - The electrical outlet, near garage door #1, was missing its weatherproof enclosure.
Recent events (3)
- · F (O) $0
- · C (O) $0
- · Z (O) $0
More inspections at YRC Freight
View YRC Freight's full OSHA safety record →
More inspections in this industry (NAICS 484122)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344690102.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.