DFW AIRPORT, TX —
OSHA Inspection: GAT AIRLINE GROUND SUPPORT, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of GAT AIRLINE GROUND SUPPORT, INC. in 2417 N SUPPORT ROAD, DFW AIRPORT, TX 75261 (NAICS 488119). OSHA activity number 344690508.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GAT AIRLINE GROUND SUPPORT, INC.
- Site address
- 2417 N SUPPORT ROAD
- City
- DFW AIRPORT
- State
- TX
- ZIP
- 75261
- Mailing
- 2417 N SUPPORT ROAD, DFW AIRPORT, TX 75261
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488119
- Employees
- 14
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.134 D01 III
- Issued
- Apr 10, 2020
- Abate by
- May 8, 2020
- Penalty
- Initial $4,424 · Current $4,424
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: In the warehouse, the employer did not evaluate the respiratory hazards in the workplace while gasoline powered forklifts were allowed to run exposing employees to carbon monoxide.
Recent events (1)
- — Z (S) $4424
1910.178 P01
- Issued
- Apr 10, 2020
- Abate by
- May 8, 2020
- Penalty
- Initial $4,424 · Current $4,424
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition: In the warehouse, employees were operating a Hyster forklift with damaged tires. The employer did not remove the Hyster forklift from service. The employees were potentially exposed to a struck-by hazard.
Recent events (1)
- — Z (S) $4424
1910.132 D02
- Issued
- Apr 10, 2020
- Abate by
- May 8, 2020
- Penalty
- Initial $828 · Current $828
General-duty citation text
29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment: At this establishment, the employer did not certify a workplace hazard assessment was performed. Employees were potentially exposed to respiratory and skin irritation when performing tasks such as, but not limited to performing warehouse duties.
Recent events (1)
- — Z (O) $828
1910.157 C01
- Issued
- Apr 10, 2020
- Abate by
- May 8, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury. In the warehouse, a portable fire extinguisher was blocked by stored material exposing employees to the hazard of smoke inhalation and fire.
Recent events (1)
- — Z (O) $0
1910.303 G01
- Issued
- Apr 10, 2020
- Abate by
- May 8, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: In the warehouse, the employer did not ensure that the area around the overhead light disconnect electric panel box was kept clear for safe operation.
Recent events (1)
- — Z (O) $0
1910.305 B02 I
- Issued
- Apr 10, 2020
- Abate by
- May 8, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: In the warehouse, the employer did not ensure that the 100 amps electrical box had a cover exposing employees to an electrical hazard.
Recent events (1)
- — Z (O) $0
More inspections at GAT Airline Ground Support, INC.
View GAT Airline Ground Support, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 488119)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344690508.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.