Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BEN E. KEITH COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BEN E. KEITH COMPANY in 7650 WILL ROGERS BLVD, FORT WORTH, TX 76140 (NAICS 424410). OSHA activity number 344692017.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch BEN E. Keith Company — free Get an email when a new federal OSHA severe-injury report for BEN E. Keith Company is published. One employer, no account, unsubscribe in one click.
Site address
7650 WILL ROGERS BLVD
City
FORT WORTH
State
TX
ZIP
76140
Mailing
7650 WILL ROGERS BLVD, FORT WORTH, TX 76140
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424410
Employees
900
Ownership type
A

2 citations on file for this inspection.

1910.119 D03 II

Serious Gravity 10 2 instances 3 exposed
Issued
Aug 4, 2020
Abate by
Sep 1, 2020
Penalty
Initial $12,145 · Current $8,000 Reduced
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices.    On or about March 10, 2020, and times prior thereto, the employer did not document that equipment complied with recognized and generally good engineering practices (RAGAGEP) for the following:    a. The door leading from the exterior parking lot into the Engine Room was not self-closing.  The employer did not document compliance with RAGAGEP such as, but not limited to, IIAR Standard 2 (2014) - Standard for Safe Design of Closed-Circuit Ammonia Refrigeration System, Section 6.10.2.  This hazardous condition allowed unauthorized personnel access to a controlled area.    b. The pressure relief valves on compressors RB-2, RB-3, RC-1, RC-2, and RC-3 were not recertified or replaced on the 5-year time-based frequency.  The employer did not document compliance with RAGAGEP such as, but not limited to, IIAR Standard 6 (2019) - Standard for Inspection, Testing, and Maintenance of Closed-Circuit Ammonia Refrigeration Systems, Section 13.1.1.
Recent events (2)
  • — I (S) $8000
  • — Z (S) $12145

1910.134 G01 I A

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 4, 2020
Abate by
Sep 1, 2020
Penalty
Initial $12,145 · Current $8,000 Reduced
29 CFR 1910.134(g)(1)(i)(A): The employer shall not permit respirators with tight-fitting facepieces to be worn by employees who have facial hair that comes between the sealing surface of the facepiece and the face or that interferes with valve function.    On or about March 10, 2020, and times prior thereto, the employer allowed tight-fitting respirators to be worn by employees with facial hair that came between the sealing surface of the facepiece.
Recent events (2)
  • — I (S) $8000
  • — Z (S) $12145

View BEN E. Keith Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344692017.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.