WASHINGTON, DC —
OSHA Inspection: VELASQUEZ BROTHERS CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VELASQUEZ BROTHERS CONSTRUCTION LLC in 5053 LOUGHBORO RD NW, WASHINGTON, DC 20016 (NAICS 238130). OSHA activity number 344692801.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VELASQUEZ BROTHERS CONSTRUCTION LLC
- Site address
- 5053 LOUGHBORO RD NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20016
- Mailing
- 14062 RANDOLPH CT, WOODBRIDGE, VA 22193
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 8
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.100 A
- Issued
- Sep 10, 2020
- Abate by
- Sep 16, 2020
- Penalty
- Initial $1,966 · Current $1,966
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about March 10, 2020; ground and lower level; employee working on lower levels removing debris during the framing process was not wearing head protection to protect against falling objects like tools being used on the upper level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $1966
1926.102 A01
- Issued
- Sep 10, 2020
- Abate by
- Sep 16, 2020
- Penalty
- Initial $2,949 · Current $2,949
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) On or about March 10, 2020; roof area; employees were not wearing the eye protection provided while operating portable equipment such as but not limited to pneumatic nail guns while conducting framing work and/or installing the trusses. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet)
Recent events (1)
- — Z (S) $2949
1926.501 B13
- Issued
- Sep 10, 2020
- Abate by
- Sep 17, 2020
- Penalty
- Initial $4,048 · Current $4,048
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about March 10, 2020; roof area; employees were exposed to an estimated 27-foot fall hazard while installing the trusses without any fall protection. b) On or about March 10, 2020; second floor area; employees were exposed to an estimated 10 foot fall hazard when conducting framing work near unguarded floor openings. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $4048
1926.1053 B01
- Issued
- Sep 10, 2020
- Abate by
- Sep 16, 2020
- Penalty
- Initial $2,949 · Current $2,949
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. a) On or about March 10, 2020; second floor; employees used a 6 foot Werner step ladder to gain access to the top plate area, and the side rails could not extend above the upper landing which was 10 feet high. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $2949
1926.1053 B13
- Issued
- Sep 10, 2020
- Abate by
- Sep 16, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) On or about March 10, 2020; second floor; the 6 foot Werner step-ladder used to access the work area was 4-feet too short, forcing the employees to use the top-step. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $0
1926.503 B01
- Issued
- Sep 10, 2020
- Abate by
- Sep 17, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) On or about March 10, 2020; throughout the site; the employer had not certified the fall protection training for employees exposed to an estimated 27-foot fall hazard while conducting framing work. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (O) $0
More inspections at Velasquez Brothers Construction LLC
View Velasquez Brothers Construction LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344692801.