Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VELASQUEZ BROTHERS CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VELASQUEZ BROTHERS CONSTRUCTION LLC in 5053 LOUGHBORO RD NW, WASHINGTON, DC 20016 (NAICS 238130). OSHA activity number 344692801.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Velasquez Brothers Construction LLC — free Get an email when a new federal OSHA severe-injury report for Velasquez Brothers Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
5053 LOUGHBORO RD NW
City
WASHINGTON
State
DC
ZIP
20016
Mailing
14062 RANDOLPH CT, WOODBRIDGE, VA 22193
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
8
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 10, 2020
Abate by
Sep 16, 2020
Penalty
Initial $1,966 · Current $1,966
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a) On or about March 10, 2020; ground and lower level; employee working on lower levels removing debris during the framing process was not wearing head protection to protect against falling objects like tools being used on the upper level.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $1966

1926.102 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 10, 2020
Abate by
Sep 16, 2020
Penalty
Initial $2,949 · Current $2,949
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  a) On or about March 10, 2020; roof area; employees were not wearing the eye protection provided while operating portable equipment such as but not limited to pneumatic nail guns while conducting framing work and/or installing the trusses.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet)
Recent events (1)
  • — Z (S) $2949

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 10, 2020
Abate by
Sep 17, 2020
Penalty
Initial $4,048 · Current $4,048
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) On or about March 10, 2020; roof area; employees were exposed to an estimated 27-foot fall hazard while installing the trusses without any fall protection.    b) On or about March 10, 2020; second floor area; employees were exposed to an estimated 10 foot fall hazard when conducting framing work near unguarded floor openings.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4048

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 10, 2020
Abate by
Sep 16, 2020
Penalty
Initial $2,949 · Current $2,949
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.   a) On or about March 10, 2020; second floor; employees used a 6 foot Werner step ladder to gain access to the top plate area, and the side rails could not extend above the upper landing which was 10 feet high.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $2949

1926.1053 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 10, 2020
Abate by
Sep 16, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:   a) On or about March 10, 2020; second floor; the 6 foot Werner step-ladder used to access the work area was 4-feet too short, forcing the employees to use the top-step.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1926.503 B01

Other-than-serious 1 instance 4 exposed
Issued
Sep 10, 2020
Abate by
Sep 17, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.  a) On or about March 10, 2020; throughout the site; the employer had not certified the fall protection training for employees exposed to an estimated 27-foot fall hazard while conducting framing work.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (O) $0

View Velasquez Brothers Construction LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344692801.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.