MEDWAY, MA —
OSHA Inspection: ROADTEX TRANSPORTATION CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ROADTEX TRANSPORTATION CORPORATION in 51 ALDER STREET, MEDWAY, MA 02053 (NAICS 484110). OSHA activity number 344694682.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROADTEX TRANSPORTATION CORPORATION
- Site address
- 51 ALDER STREET
- City
- MEDWAY
- State
- MA
- ZIP
- 02053
- Mailing
- 51 ALDER STREET, MEDWAY, MA 02053
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484110
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.178 L01 I
- Issued
- May 6, 2020
- Abate by
- Jun 25, 2020
- Penalty
- Initial $2,892 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): Worksite: The employer did not train a new fork truck operator.
Recent events (2)
- — I (S) $1200
- — Z (S) $2892
1910.178 M08
- Issued
- May 6, 2020
- Abate by
- Jun 25, 2020
- Penalty
- Initial $2,892 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(m)(8): There shall be sufficient headroom under overhead installations, lights, pipes, sprinkler system, etc Loading Dock: Sufficient clearance was not provided between a Crown Forklift and the raised rear door of a trailer.
Recent events (2)
- — I (S) $0
- — Z (S) $2892
More inspections in this industry (NAICS 484110)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344694682.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.