ARLINGTON HEIGHTS, IL ·
OSHA Inspection: GARCIA'S EXTERIOR & INTERIOR REMODELING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GARCIA'S EXTERIOR & INTERIOR REMODELING, INC. in 1316 ARLINGTON HEIGHTS ROAD, ARLINGTON HEIGHTS, IL 60005 (NAICS 238160). OSHA activity number 344696687.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GARCIA'S EXTERIOR & INTERIOR REMODELING, INC.
- Site address
- 1316 ARLINGTON HEIGHTS ROAD
- City
- ARLINGTON HEIGHTS
- State
- IL
- ZIP
- 60005
- Mailing
- 6831 JUNIPER STREET, HANOVER PARK, IL 60133
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.28 A
- Issued
- Apr 17, 2020
- Abate by
- Apr 23, 2020
- Penalty
- Initial $2,313 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions: a) On or about March 13, 2020, employees were not provided with appropriate foot protection to guard against punctures and lacerations to the feet when required to work on and in roofing debris containing nails. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $1000
- · Z (S) $2313
1926.501 B10
- Issued
- Apr 17, 2020
- Penalty
- Initial $4,048 · Current $2,825 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. a) On or about March 13, 2020, employees were exposed to the hazard of falling while performing roofing work without the benefit of fall protection from a low-slope roof having a pitch of approximately 5/12 and a ground to eave height of approximately 12 feet. No abatement certification or documentation required for this violation.
Recent events (2)
- · I (S) $2825
- · Z (S) $4048
1926.503 B01
- Issued
- Apr 17, 2020
- Abate by
- Jul 13, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record: a) On or about March 13, 2020, the employer did not prepare written certification records related to employee fall protection training. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (O) $0
- · Z (O) $0
1926.1053 B01
- Issued
- Apr 17, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On or about March 13, 2020, a portable ladder used to access the roof elevation of the building did not extend at least 3 feet above the landing surface. No abatement certification or documentation required for this violation.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344696687.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.