Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: VENTAMATIC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VENTAMATIC in 100 WASHINGTON AVE, MINERAL WELLS, TX 76067 (NAICS 423730). OSHA activity number 344707385.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ventamatic for free Get an email when a new federal OSHA severe-injury report for Ventamatic is published. One employer, no account, unsubscribe in one click.
Establishment
VENTAMATIC
Site address
100 WASHINGTON AVE
City
MINERAL WELLS
State
TX
ZIP
76067
Mailing
100 WASHINGTON AVE, MINERAL WELLS, TX 76067
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423730
Employees
320
Ownership type
Private (A)

2 citations on file for this inspection.

1910.217 C02 I

Serious Gravity 10 1 instance 3 exposed
Issued
May 1, 2020
Abate by
Jun 1, 2020
Penalty
Initial $13,494 · Current $8,096 Reduced
29 CFR 1910.217(c)(2)(i): It shall prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard.   In the brake press machine area, employees engaged in cutting metal parts with an unguarded hydraulic brake press machine were exposed to caught-in and amputation hazards when reaching into the pinch point/cutting area.
Recent events (2)
  • · I (S) $8096.4
  • · Z (S) $13494

1910.217 C02 VII

Serious Gravity 10 1 instance 3 exposed
Issued
May 1, 2020
Abate by
Jun 1, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.217(c)(2)(vii): Point of operation enclosures on mechanical power press(es), which did not meet the requirements of this subparagraph and Table O-10, were not used in conjunction with point of operation devices.    In the brake press machine area, the employer did not ensure a hydraulic brake press machine met point of operation guarding based on the requirements of table O-10 when employees were cutting material at or over 1/4 inch width.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344707385.