Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BULLDOG RACK OF WEIRTON, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BULLDOG RACK OF WEIRTON, INC. in 200 FORT STEUBEN ROAD, WEIRTON, WV 26062 (NAICS 337215). OSHA activity number 344713532.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bulldog Rack of Weirton, INC. — free Get an email when a new federal OSHA severe-injury report for Bulldog Rack of Weirton, INC. is published. One employer, no account, unsubscribe in one click.
Site address
200 FORT STEUBEN ROAD
City
WEIRTON
State
WV
ZIP
26062
Mailing
200 FORT STEUBEN ROAD, WEIRTON, WV 26062
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337215
Employees
90
Ownership type
A

8 citations on file for this inspection.

1910.147 C06

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 25, 2020
Abate by
Oct 30, 2020
Penalty
Initial $9,446 · Current $4,723 Reduced
29 CFR 1910.147(c)(6): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  The periodic inspection must: [A] be performed by an authorized employee other than the ones utilizing the energy control procedure being inspected.   [B] be conducted to correct any deviations or inadequacies identified. [C] where lockout is used for energy control, include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected. [D] where tag-out is used for energy control, include a review between the inspector and each authorized and affected employee, of that employee's responsibilities under the energy control procedure being inspected, and the elements set forth in paragraph (c)(7)(ii) of this section.  (a) Throughout the facility - On or about 3/28/2020, the employer did not conduct periodic inspections to protect employees performing changeovers, servicing, and maintenance on hazardous machinery, exposing employees to amputation hazards.
Recent events (3)
  • — F (S) $4723
  • — C (S) $9446
  • — Z (S) $9446

1910.147 C07 I

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 25, 2020
Abate by
Oct 30, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:  (a) Throughout the facility - On or about 3/28/2020, the employer did not provide effective training to employees for the application, utilization, and removal of energy control devices, exposing employees to amputation hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 25, 2020
Abate by
Oct 22, 2020
Penalty
Initial $9,446 · Current $4,723 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  (a) 3x3 Roll Former - On or about 3/31/20, the forming rolls of the machine were not guarded to prevent employees from entering the danger zone while the machine was operating, exposing employees to amputation hazards.
Recent events (3)
  • — F (S) $4723
  • — C (S) $9446
  • — Z (S) $9446

1910.219 C04 I

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 25, 2020
Abate by
Oct 22, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft:  (a) 3x3 Roll Former - On or about 3/31/20, the machine had rotating shaft ends which projected greater than one-half their diameter and were not guarded, exposing employees to caught-in hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.219 H01

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 25, 2020
Abate by
Oct 22, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.219(h)(1): Projecting key(s), setscrew(s), or other projections in revolving part(s) were not removed, made flush, or guarded by metal cover(s):  (a) 3x3 Roll Former - On or about 3/31/20, the machine had a rotating shaft with a projecting pin which was not removed, made flush, or guarded, exposing employees to caught-in hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.217 C02 I B

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 25, 2020
Abate by
Oct 15, 2020
Penalty
Initial $6,747 · Current $3,373 Reduced
29 CFR 1910.217(c)(2)(i)(b): Point of operation guard(s) on mechanical power press(es) did not conform to the maximum permissible opening(s) specified in Table O-10:  (a) #60 Beam Blanker - On or about 3/31/2020, employees were operating a mechanical power press with guard openings of 8.5 inches in its least dimension and located 12 inches from the point of operation, exposing employees to amputation hazards.  (b) 3x3 punch press - On or about 3/31/2020, employees were operating a mechanical power press with no guarding present, exposing employees to amputation hazards.
Recent events (3)
  • — F (S) $3373
  • — C (S) $6747
  • — Z (S) $6747

1910.147 C04 I

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 25, 2020
Abate by
Oct 30, 2020
Penalty
Initial $107,950 · Current $53,975 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) 3x3 Roll former cutoff - On or about 3/28/2020, the employer allowed employees to perform work on hazardous machinery which required the bypassing of guards and placing the employees body within the danger zone of the machine without utilizing lockout procedures, exposing employees to amputation hazards.
Recent events (3)
  • — F (S) $53975
  • — C (W) $107950
  • — Z (W) $107950

1910.141 A05

Other-than-serious 1 instance 5 exposed
Issued
Sep 25, 2020
Abate by
Oct 5, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.141(a)(5): Enclosed workplaces were not so constructed, equipped, and maintained as to prevent the entrance or harborage of rodents, insects, or other vermin:  (a) Office - On or about 8/28/2020, the employer did not maintain the workplace to prevent the entrance and harborage of rodents, exposing employees to biological hazards.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Bulldog Rack of Weirton, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344713532.