Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HACKENSACK MERIDIAN HEALTH HOSPITALS CORPORATION

Federal Agency inspection · Health discipline

On , OSHA opened a federal Agency health inspection of HACKENSACK MERIDIAN HEALTH HOSPITALS CORPORATION in 30 PROSPECT AVE., HACKENSACK, NJ 07601 (NAICS 622110). OSHA activity number 344722954.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hackensack Meridian Health Hospitals Corporation — free Get an email when a new federal OSHA severe-injury report for Hackensack Meridian Health Hospitals Corporation is published. One employer, no account, unsubscribe in one click.
Site address
30 PROSPECT AVE.
City
HACKENSACK
State
NJ
ZIP
07601
Mailing
343 THORNALL STREET, EDISON, NJ 08837
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
622110
Employees
8000
Ownership type
A

2 citations on file for this inspection.

1910.134 F02

Deleted Serious Gravity 10 2 instances 10 exposed
Issued
Oct 29, 2020
Abate by
Nov 23, 2020
Penalty
Initial $13,494 · Current $0 Reduced
29 CFR 1910.134(f)(2): The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter.  (a) ICUs, 3 Pavilion East, 5 Pavilion East: Employees working as Respiratory Therapists were required to wear N95 filtering facepiece respirators while providing direct patient care to COVID-19 positive patients.  The employer did not ensure the employees received annual fit tests, on and after 4/29/2020.   (b) ICUs, 3 Pavilion East, 5 Pavilion East: Employees working as Respiratory Therapists were required to wear N95 filtering facepiece respirators while providing direct patient care to COVID-19 positive patients.  The employer did not ensure that these employees were provided additional fit tests when different makes/models of N95 filtering facepiece respirators were used, on and after 4/29/2020.
Recent events (3)
  • — J (S) $0
  • — C (S) $13494
  • — Z (S) $13494

1910.134 K01 IV

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Oct 29, 2020
Abate by
Nov 23, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(1)(iv): The employer did not ensure that each user could demonstrate knowledge of how to inspect, put on, remove, use, and check the seals of the respirator:  (a) ICUs, 3 Pavilion East, 5 Pavilion East: Employees working as Respiratory Therapists are required to wear N95 filtering facepiece respirators while providing direct care to COVID-19 positive patients.  The employer did not ensure that each employee can demonstrate knowledge of how to inspect, put on, remove and check the seals their respirator on and after 4/29/2020.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

View Hackensack Meridian Health Hospitals Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344722954.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.