Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MAXIM ROOFING COMPANY, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MAXIM ROOFING COMPANY, LLC in 6121 TAYLORSVILLE ROAD, DAYTON, OH 45424 (NAICS 238160). OSHA activity number 344730007.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Maxim Roofing Company, LLC — free Get an email when a new federal OSHA severe-injury report for Maxim Roofing Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
6121 TAYLORSVILLE ROAD
City
DAYTON
State
OH
ZIP
45424
Mailing
500 WEST DAYTON DRIVE, FAIRBORN, OH 45324
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
46
Ownership type
A

4 citations on file for this inspection.

1926.1051 B

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Sep 18, 2020
Abate by
Sep 24, 2020
Penalty
Initial $9,446 · Current $0 Reduced
29 CFR 1926.1051(b): Employers shall provide and install all stairway and ladder fall protection systems required by this subpart and shall comply with all other pertinent requirements of this subpart before employees begin the work that necessitates the installation and use of stairways, ladders, and their respective fall protection systems.  On or about April 21, 2020 the Employer did not monitor or inspect the set-up and usage of the non-self-supporting sectional fiberglass Werner Model D6232-2 extension ladder used by employees for climbing or descending to a low-sloped roof to perform roofing associated roofing activities to ensure compliance with all pertinent requirements of Subpart X before employees begin the work that necessitated the installation and use of ladders to ensure the ladder was setup for regulation compliant usage with ladders safety shoes slip resistant pads or similar devices, the ladder was set up on stable and level surfaces unless secured to prevent accidental displacement, the ladder was not being used on slippery surfaces unless secured or provided with slip-resistant feet to prevent accidental displacement and that slip-resistant feet shall not be used as a substitute for care in lashing or holding a ladder that is used upon slippery surfaces including, but not limited flat metal exposing the employees climbing or descending to fall potentials in excess of 10 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9446

1926.1053 B04

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 18, 2020
Abate by
Sep 24, 2020
Penalty
Initial $9,446 · Current $3,778 Reduced
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed.    On or about April 21, 2020 a non-self-supporting sectional fiberglass Werner Model D6232-2 extension ladder was used by employees for climbing or descending to a low-sloped roof to perform roofing associated roofing activities without using the ladder for the purpose for which it was designed by Werner Ladders in that the top section of sectional Warner Ladder Model D6232-2 extension ladder was used for a bottom section without the user equipping that section with safety shoes and that the Werner Ladder Model D6232-2 extension ladders footing support was utilized without safety shoes, spikes, spurs, slip resistant pads or similar devices being used exposing the employees climbing or descending to fall potentials in excess of 10 feet.      Werner Ladders Fiberglass Ladder Technical Manual Care, Use, and Quality Control of Reinforced Plastic ladders pages 15 and 16 identify under Use of Sections of Sectional Ladders the middle and top sections of sectional ladders shall not be used for bottom sections unless the user equips them with safety shoes. Under the heading Footing Support it identifies ladders without safety shoes, spikes, spurs, slip resistant pads or similar devices shall not be used.
Recent events (2)
  • — I (S) $3778
  • — Z (S) $9446

1926.1053 B06

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 18, 2020
Abate by
Sep 24, 2020
Penalty
Initial $9,446 · Current $0 Reduced
29 CFR 1926.1053(b)(6): Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement.    On or about April 21, 2020 a non-self-supporting sectional fiberglass Werner Model D6232-2 extension ladder was used by employees for climbing or descending to a low-sloped roof to perform roofing associated activities with the top section of the sectional Warner Ladder Model D6232-2 extension ladder being utilized as the bottom section without ensuring the ladder base or bottom section was secured from displacement or stable on its resting surface due to the base the surfaces that the unsecured bottom side rails sections notched plastic side rail end caps contact with the concrete surface created an unstable resting surface as utilized exposing the employees climbing or descending to fall potentials in excess of 10 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9446

1926.1053 B07

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 18, 2020
Abate by
Sep 24, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(7): Ladders shall not be used on slippery surfaces unless secured or provided with slip-resistant feet to prevent accidental displacement. Slip-resistant feet shall not be used as a substitute for care in placing, lashing, or holding a ladder that is used upon slippery surfaces including, but not limited to, flat metal or concrete surfaces that are constructed so they cannot be prevented from becoming slippery.    On or about April 21, 2020 a non-self-supporting sectional fiberglass Werner Model D6232-2 extension ladder was used by employees for climbing or descending to a low-sloped roof to perform roofing associated activities with the utilized top section of the sectional Warner Ladder Model D6232-2 extension ladder side rails being placed against the roof parapet flashing creating a slippery surfaces between the resting side rails and roof parapet metal flashing without  holding or lashing the top area of the extension ladders side rails or rungs exposing the employees climbing or descending to fall potentials in excess of 10 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Maxim Roofing Company, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344730007.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.