LIGHTHOUSE POINT, FL ·
OSHA Inspection: D CATALAN CONSTRUCTION, LLC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of D CATALAN CONSTRUCTION, LLC. in 2783 NE 31ST COURT, LIGHTHOUSE POINT, FL 33064 (NAICS 238140). OSHA activity number 344735600.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D CATALAN CONSTRUCTION, LLC.
- Site address
- 2783 NE 31ST COURT
- City
- LIGHTHOUSE POINT
- State
- FL
- ZIP
- 33064
- Mailing
- 5844 S.E. COLLINS AVE., STUART, FL 34997
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 9
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1903.19 C01
- Issued
- Sep 30, 2021
- Abate by
- Nov 4, 2021
- Penalty
- Initial $329 · Current $329
General-duty citation text
29 CFR 1903.19(c)(1):The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: a) On or about 08/10/2021, the employer failed to submit certification of corrective action for citation 1, item 1b, issued on 09/08/2020 with an abatement due date of 09/18/2020. b) On or about 08/10/2021, the employer failed to submit certification of corrective action for citation 1, item 2a, issued on 09/08/2020 with an abatement due date of 09/18/2020. c) On or about 08/10/2021, the employer failed to submit certification of corrective action for citation 1, item 2b, issued on 09/08/2020 with an abatement due date of 09/18/2020. c) On or about 08/10/2021, the employer failed to submit certification of corrective action for citation 1, item 2c, issued on 09/08/2020 with an abatement due date of 09/18/2020.
Recent events (1)
- · Z (O) $329
1903.19 D01
- Issued
- Sep 30, 2021
- Abate by
- Nov 18, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required: a) On or about 08/10/2021, the employer failed to submit documentation and certification of corrective action for citation 1, item 1a, issued on 09/08/2020 with an abatement due date of 09/18/2020.
Recent events (1)
- · Z (O) $0
1926.416 A01
- Issued
- Sep 8, 2020
- Abate by
- Sep 18, 2020
- Penalty
- Initial $4,048 · Current $4,048
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: On or about September 27, 2020, on the right side of the front of the new home under construction, located at 2783 NE 31st. Ct. Lighthouse Point, FL, an employee was exposed to an electrocution hazard while attaching pallets of lintels on to a crane joist which was located within approximately 5 feet or less of overhead power lines energized with 7,600 volts.
Recent events (1)
- · Z (S) $4048
1926.416 A03
- Issued
- Sep 8, 2020
- Abate by
- Sep 18, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(a)(3): Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into pysical or electrical contact with the electric power circuit: On or about September 27, 2020, on the right side of the front of the new home under construction, located at 2783 NE 31st. Ct. Lighthouse Point, FL, an employee was working within approximately 5 feet or less of overhead power lines energized with 7,600 volts, without the employer conducting an assessment of the powerlines before allowing the employee to commence work, exposing the employee to a electrocution hazard.
Recent events (1)
- · Z (S) $0
1926.501 B13
- Issued
- Sep 8, 2020
- Abate by
- Sep 18, 2020
- Penalty
- Initial $2,313 · Current $2,313
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about September 27, 2020, on the top of the second floor of the new home under construction, located at 2783 NE 31st. Ct. Lighthouse Point, FL, an employee was working without the use of fall protection, exposing the employee to a fall hazard of approximately 10 feet.
Recent events (1)
- · Z (S) $2313
1926.503 A01
- Issued
- Sep 8, 2020
- Abate by
- Sep 18, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On or about September 27, 2020, on the top of the second floor of the new home under construction, located at 2783 NE 31st. Ct. Lighthouse Point, FL, an employee was working without the use of fall protection nor fall protection training exposing the employee to a fall hazard of approximately 10 feet.
Recent events (1)
- · Z (S) $0
1926.20 B02
- Issued
- Sep 8, 2020
- Abate by
- Sep 18, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): On or about September 27, 2020, on the right side of the front of the new home under construction, located at 2783 NE 31st. Ct. Lighthouse Point, FL, an employee was working on the second floor of the home without the employer conducting a jobsite inspection before allowing the employee to commence work, exposing the employee to a fall hazard of approximately 10 feet.
Recent events (1)
- · Z (S) $0
More inspections in this industry (NAICS 238140)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344735600.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.