Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: NOE CRUZ BARRERA

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NOE CRUZ BARRERA in 834 NAGLE ST, HOUSTON, TX 77003 (NAICS 238220). OSHA activity number 344741814.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NOE Cruz Barrera for free Get an email when a new federal OSHA severe-injury report for NOE Cruz Barrera is published. One employer, no account, unsubscribe in one click.
Establishment
NOE CRUZ BARRERA
Site address
834 NAGLE ST
City
HOUSTON
State
TX
ZIP
77003
Mailing
801 NORELL ST, CHANNELVIEW, TX 77530
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
2
Ownership type
Private (A)

4 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 19, 2020
Abate by
Jun 26, 2020
Penalty
Initial $4,048 · Current $4,048
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):  a) At the jobsite, the employer did not perform frequent and regular inspections of the job site, materials and equipment for safety hazards, exposing workers to fall hazards.
Recent events (1)
  • · Z (S) $4048

1926.501 B14

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 19, 2020
Abate by
Jun 26, 2020
Penalty
Initial $4,048 · Current $4,048
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached) where the outside bottom edge of the wall opening is 6 feet or more above lower levels and the inside bottom edge of the wall opening:  a) At the jobsite, an employee installing caulking around HVAC vents was not protected by a safety net, guardrails or personal fall arrest system at the fourth-floor elevator shaft, exposing the employee to fall hazards.
Recent events (1)
  • · Z (S) $4048

1926.503 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 19, 2020
Abate by
Jul 9, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not train each employee who might be exposed to fall hazards to enable them to recognize fall hazards and the procedures to be followed in order to minimize these hazards:  a) At the jobsite, one employee was installing caulking to HVAC vents in the town house under construction and had not been trained on the hazards associated with falls, exposing the employee to a fall hazard up to approximately 45 feet.
Recent events (1)
  • · Z (S) $0

1926.1052 C01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 19, 2020
Abate by
Jun 26, 2020
Penalty
Initial $1,735 · Current $1,735
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:  a) At the jobsite, the stairways leading to all four floors of the town house under construction were not equipped with handrails, exposing employees to slip, trip and falls.
Recent events (1)
  • · Z (S) $1735

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344741814.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.