Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NORDEST SERVICES LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of NORDEST SERVICES LLC in 341 9TH AVENUE, NEW YORK, NY 10199 (NAICS 238910). OSHA activity number 344750807.

Watch Nordest Services LLC — free Get an email when a new federal OSHA severe-injury report for Nordest Services LLC is published. One employer, no account, unsubscribe in one click.
Site address
341 9TH AVENUE
City
NEW YORK
State
NY
ZIP
10199
Mailing
60-31 60TH PLACE, MASPETH, NY 11378
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
12
Ownership type
A

2 citations on file for this inspection.

1926.21 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $13494.00 · Current $10000.00 Reduced
29 CFR  1926.21(b)(2):The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury:  Location: 341 9th Avenue, New York, NY 10199  On or about: May 13, 2020  (a) Employees were not trained in the recognition and avoidance of struck by hazards while performing fire extinguisher recharge procedures.
Recent events (2)
  • — I (S) $10000
  • — Z (S) $13494

1926.150 C01 VIII

Serious Gravity 10 4 instances 2 exposed
Issued
Abate by
Penalty
Initial $13494.00 · Current $10000.00 Reduced
29 CFR 1926.150(c)(1)(viii): Portable fire extinguishers were not inspected periodically and maintained in accordance with maintenance and use of portable fire extinguishers, N.F.P.A. No. 10A-1970:  Location: 341 9th Avenue, New York, NY 10199    On or about: May 13, 2020  Badger WP-61 Water Stored Pressure Fire Extinguishers were not inspected and maintained in accordance with N.F.P.A. No. 10A-1970. Employees were recharging the fire extinguishers when one ruptured, resulting in the death of one employee and the hospitalization of another:    (a) Employees were instructed by the employer to recharge the fire extinguishers by using the extinguisher gauge as an indicator of charge pressure, instead of regulating the pressure at the source per the recharge instructions on the fire extinguisher nameplate. This is not in accordance with the requirements of N.F.P.A. No. 10A - 1970, Paragraph 3410 which states that the recharging instructions on the nameplate of the fire extinguisher must be used.  (b) Employees were instructed by the employer to pressurize the fire extinguishers with oxygen, rather than air or nitrogen as specified on the fire extinguisher nameplate. This is not in accordance with the requirements of N.F.P.A. No 10A - 1970, Paragraph 3430 which states that only those recharging materials specified on the extinguisher nameplate be used.
Recent events (2)
  • — I (S) $10000
  • — Z (S) $13494

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344750807.