OSHA Inspection: J.A.P. HOME IMPROVEMENT INC.

Fatality or catastrophe inspection · Safety discipline

On , OSHA opened a fatality or catastrophe safety inspection of J.A.P. HOME IMPROVEMENT INC. in 306 SOUTHERN AVE SE, WASHINGTON, DC 20032 (NAICS 238130). OSHA activity number 344759535.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J.A.P. Home Improvement INC. for free Get an email when a new federal OSHA severe-injury report for J.A.P. Home Improvement INC. is published. One employer, no account, unsubscribe in one click.
Site address
306 SOUTHERN AVE SE
City
WASHINGTON
State
DC
ZIP
20032
Mailing
925 MONTROSE AVE, LAUREL, MD 20707
Inspection type
Fatality or catastrophe (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
24
Ownership type
Private (A)

3 citations on file for this inspection.

1926.502 B03

Serious Gravity 10 1 instance 8 exposed
Issued
Nov 19, 2020
Abate by
Nov 25, 2020
Penalty
Initial $13,494 · Current $7,250 Reduced
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge:  a) On or about May 19, 2020; top-floor area; Employees performing housekeeping and framing related tasks were exposed to a 40 to 50 foot fall hazard in that the construction of the guardrail system, including, but not limited to 12 foot long spans of railing without additional bracing, and attached to the outside of the vertical posts, did not meet the 200 pound requirement.   b) On or about May 19, 2020; top-floor area; Employees performing housekeeping and framing related tasks were exposed to a 40 to 50 foot fall hazard in that the construction of the guardrail system, including, but not limited to the securing of the vertical posts, did not meet the 200 pound requirement.   c) On or about May 19, 2020; top-floor area; Employees performing housekeeping and framing related tasks were exposed to a 40 to 50 foot fall hazard in that the construction of the guardrail system, including, but not limited to the number of nails used to secure the system, did not meet the 200 pound requirement.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $7250
  • · Z (S) $13494

1926.503 A02 II

Serious Gravity 10 1 instance 8 exposed
Issued
Nov 19, 2020
Abate by
Nov 30, 2020
Penalty
Initial $13,494 · Current $7,250 Reduced
29 CFR  1926.503(a)(2)(ii): The employer did not assure that each employee, as necessary, had been trained by a competent person in the correct procedures for erecting, maintaining, disassembling and inspecting the fall protection systems to be used:   a) On or about May 19, 2020; Top-floor area; Employees conducting carpentry work were exposed to a 40 to 50 foot fall hazard due to an improperly erected guardrail system and were not trained in the correct procedures for erecting and inspecting the system.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $7250
  • · Z (S) $13494

1904.4 A

Other-than-serious 1 instance 4 exposed
Issued
Nov 19, 2020
Abate by
Nov 30, 2020
Penalty
Initial $656 · Current $500 Reduced
29 CFR 1904.4(a): The employer did not record each work-related fatality, injury or illness case that resulted in the general recording criteria on the OSHA Form 300 or equivalent.   a) On or about June 8, 2020; The employer had not recorded on the OSHA Form 300 or equivalent for the calendar year 2020 a work-related fall that occurred on May 19, 2020 and resulted in injuries requiring hospitalization and days away from work.   b) On or about June 8, 2020; The employer had not recorded on the OSHA Form 300 or equivalent for the calendar year 2020 a work-related fall that occurred on May 19, 2020 and resulted in an employee fatality.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet