Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: G. A. CARLSON & COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of G. A. CARLSON & COMPANY in 430 CRAZY HORSE RD, FAYETTEVILLE, WV 25840 (NAICS 238130). OSHA activity number 344777230.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G. a. Carlson & Company for free Get an email when a new federal OSHA severe-injury report for G. a. Carlson & Company is published. One employer, no account, unsubscribe in one click.
Site address
430 CRAZY HORSE RD
City
FAYETTEVILLE
State
WV
ZIP
25840
Mailing
372 BELMONT ROAD, FAYETTEVILLE, WV 25840
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
Private (A)

5 citations on file for this inspection.

1926.100 A

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 4, 2020
Abate by
Aug 10, 2020
Penalty
Initial $4,048 · Current $2,500 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    a) 2nd floor of new home on 430 Crazy Horse Rd: On or about June 4, 2019 and times prior, employees were installing cross braces on trusses of a new two story residential home. The employee working at floor level did not utilize head protection while the employee in the rafters worked with heavy power tools such as nail guns and saws.
Recent events (2)
  • · I (S) $2500
  • · Z (S) $4048

1926.501 C03

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Aug 4, 2020
Abate by
Aug 10, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.501(c)(3): The employer did not barricade the area to which objects could fall, did not prohibit employees from entering the barricaded area, and did not keep objects that could fall far enough away from the edge of a higher level so that objects would not go over the edge if they were accidently displaced.   a) 430 Crazy Horse Rd: On or about June 4, 2020 and times prior, employees used power tools while working in the rafters on a new two story residential home.  The area below was not barricaded to prevent entry and tools were not secured or moved to prevent falling off of the rafter beams.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 4, 2020
Abate by
Aug 10, 2020
Penalty
Initial $2,892 · Current $1,250 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     a) 2nd floor 430 Crazy Horse Rd: On or about June 10, 2020, an employee was exposed to a fall of 25 feet, building edge to ground while installing braces on trusses of a new residential home.  The employee was not utilizing a fall protection system.
Recent events (2)
  • · I (S) $1250
  • · Z (S) $2892

1926.405 G02 IV

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 4, 2020
Penalty
Initial $1,735 · Current $1,250 Reduced
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:    a) 430 Crazy Horse Rd: On or about June 4, 2020 and times prior, employees operated a reciprocating saw with the strain relief on the power cord separated from the equipment.
Recent events (2)
  • · I (S) $1250
  • · Z (S) $1735

1926.1052 C01

Other-than-serious 1 instance 2 exposed
Issued
Aug 4, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge:  a) Front entrance to home: On or about June 10, 2020, employees used the stairway on the front of the home to gain access to the home.  The stairway was equipped with five risers and was not equipped with a stairrail system on the unprotected side.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344777230.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.