NOKOMIS, FL —
OSHA Inspection: PGT INDUSTRIES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PGT INDUSTRIES, INC. in 1070 TECHNOLOGY DRIVE, NOKOMIS, FL 34275 (NAICS 332321). OSHA activity number 344794532.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PGT INDUSTRIES, INC.
- Site address
- 1070 TECHNOLOGY DRIVE
- City
- NOKOMIS
- State
- FL
- ZIP
- 34275
- Mailing
- 1070 TECHNOLOGY DRIVE, NOKOMIS, FL 34275
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- Employees
- 3
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 F01
- Issued
- Nov 20, 2020
- Abate by
- Feb 1, 2021
- Penalty
- Initial $9,639 · Current $7,229 Reduced
General-duty citation text
29 CFR 1910.147(f)(1): When lockout or tagout devices temporarily were removed from the energy isolating device and the machine or equipment was energized to test or position the machine, equipment or component thereof, the sequence of actions in 29 CFR(f)(i-v) ) On or about 6/23/2020, at the Glass Plant, a trouble shooting was done in the machine , Lami 1 BillCo Glasses Washer, and the written procedure did not address what sequence of actions needed to be followed: i. Clear the machine from tools and materials in accordance with paragraph (e)(1) of this section; ii. Remove employees from the machine or equipment area in accordance with paragraph (e)(2) of this section; iii. Remove the lock out or tagout devices as specified in paragraph (e)(3) of this section; iv. Energize and proceeed with testing or positioning; v. Denergize all systems and reapply energy control measures in accordance with paragraph (d) of this section to continue the servicing and/or maintenance.
Recent events (2)
- — I (O) $7229.25
- — Z (S) $9639
More inspections at PGT Industries, INC.
View PGT Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332321)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344794532.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.