SEABROOK, TX —
OSHA Inspection: MAGNUM AIR, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of MAGNUM AIR, INC. in 2401 MEYER ROAD, SEABROOK, TX 77586 (NAICS 333415). OSHA activity number 344795083.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAGNUM AIR, INC.
- Site address
- 2401 MEYER ROAD
- City
- SEABROOK
- State
- TX
- ZIP
- 77586
- Mailing
- PO BOX 2115, MONTGOMERY, TX 77356
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- Yes
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333415
- Employees
- 56
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 F02 I
- Issued
- Nov 25, 2020
- Abate by
- Dec 22, 2020
- Penalty
- Initial $6,747 · Current $5,667 Reduced
General-duty citation text
29 CFR 1910.147(f)(2)(i): When outside servicing personnel were engaged in activities in a facility, the onsite employer and the outside employer did not inform each other of their respective lockout or tagout procedures: a) At the jobsite, Magnum Air did not exchange lockout or tagout procedures with Strategic Air when employees of Strategic Air were servicing a Carrier 50TC-A06A2A6A0A0A0 HVAC unit, exposing workers to amputation hazards.
Recent events (2)
- — I (S) $5667
- — Z (S) $6747
1910.147 C04 I
- Issued
- Nov 25, 2020
- Abate by
- Dec 22, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) At the jobsite, employees did not utilize lockout/tagout procedures exposing the employees to amputation hazards while servicing a Carrier 50TC-A06A2A6A0A0A0 HVAC unit that had not been de-energized.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Nov 25, 2020
- Abate by
- Dec 22, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) At the jobsite, lockout devices were not affixed to a Carrier 50TC-A06A2A6A0A0A0 HVAC unit prior to maintenance, exposing employees to amputation hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.333 A01
- Issued
- Nov 25, 2020
- Abate by
- Dec 31, 2020
- Penalty
- Initial $9,446 · Current $0 Reduced
General-duty citation text
29 CFR 1910.333(a)(1): Live parts to which an employee may be exposed were not deenergized before an employee worked on or near them: a) At the worksite, the electrical parts of a Carrier Model 50TC-A06A2A6A0A0A0 480-volt HVAC unit Serial Number 5114C89522 were not deenergized before employees worked near them.
Recent events (2)
- — I (S) $0
- — Z (S) $9446
1910.333 B02 II B
- Issued
- Nov 25, 2020
- Abate by
- Dec 22, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(b)(2)(ii)(B): The circuits and equipment to be worked on were not disconnected from all electric energy sources: a) At the worksite, the circuits and equipment of a Carrier Model 50TC-A06A2A6A0A0A0 480-volt HVAC unit Serial Number 5114C89522, were not disconnected from all electric energy sources while employees worked on them.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.333 B02 III A
- Issued
- Nov 25, 2020
- Abate by
- Dec 22, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(b)(2)(iii)(A): A lock and a tag were not placed on each disconnecting means used to deenergize circuits and equipment on which work was to be performed: a) At the worksite, locks and tags were not placed on the disconnecting means used to deenergize a Carrier Model 50TC-A06A2A6A0A0A0 480-volt HVAC unit Serial Number 5114C89522, on which work was being performed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.333 B02 IV B
- Issued
- Nov 25, 2020
- Abate by
- Dec 22, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(b)(2)(iv)(B): Before circuits or equipment was worked as deenergized, a qualified person did not use test equipment to test the circuit elements and electrical parts of equipment to which employees would be exposed and did not verify that the circuit elements and equipment parts were de-energized: a) At the worksite, a qualified person did not use test equipment to test the circuit elements and electrical parts of a Carrier Model 50TC-A06A2A6A0A0A0 480-volt HVAC unit Serial Number 5114C89522, to which employees were exposed and did not verify that the circuit elements and equipment parts of the HVAC unit were de-energized.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Magnum AIR, INC.
View Magnum AIR, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333415)
More inspections in TX