ARLINGTON, TX —
OSHA Inspection: OCHOA CONSTRUCTION, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OCHOA CONSTRUCTION, LLC in 2000 MAINSFIELD WEBB RD., ARLINGTON, TX 76002 (NAICS 238140). OSHA activity number 344796248.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OCHOA CONSTRUCTION, LLC
- Site address
- 2000 MAINSFIELD WEBB RD.
- City
- ARLINGTON
- State
- TX
- ZIP
- 76002
- Mailing
- 10327 HOLLYGLEN DR., HOUSTON, TX 77016
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 B01
- Issued
- Jun 29, 2020
- Penalty
- Initial $1,475 · Current $1,475
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) On the east side of the construction site, employees worked from a tubular welded frame scaffold that was not fully planked on all working levels and were exposed to a fall hazard of approximately 13-feet to the concrete or ground below.
Recent events (1)
- — Z (S) $1475
1926.451 E01
- Issued
- Jun 29, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. On the east side of the construction, the employer did not provide a scaffold ladder where the employees could access and egress the tubular welded frame scaffold safely. The employees were exposed to potential fall hazards of approximately 13 feet to the ground.
Recent events (1)
- — Z (S) $0
1926.451 F03
- Issued
- Jun 29, 2020
- Abate by
- Jul 21, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On the east side of the construction site, the employer did not ensure that all scaffolds were inspected for visible defects including, by a competent person, exposing employees to a fall hazard of approximately 13-feet to the concrete or ground below. Defects included, but not limited to not being fully planked and not having a ladder attached.
Recent events (1)
- — Z (S) $0
1926.451 F04
- Issued
- Jun 29, 2020
- Abate by
- Jul 21, 2020
- Penalty
- Initial $1,475 · Current $1,475
General-duty citation text
29 CFR 1926.451(f)(4): Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired. On the east side of the construction, the employer did not ensure visible defects in scaffolds were immediately repaired, replaced, or removed from service until repaired, exposing employees to a fall hazard of approximately 13-feet to the concrete or ground below. Defects include, but not limited to scaffold not being fully planked, no ladder placed on the scaffold and no use of fall protection.
Recent events (1)
- — Z (S) $1475
1926.451 G01 VII
- Issued
- Jun 29, 2020
- Penalty
- Initial $1,475 · Current $1,475
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. On the east side of the construction, employees were working from the second tier of a tubular welded frame scaffold without guardrails or personal fall arrest systems installing masonry material. Three employees were exposed to potential fall hazards of approximately 13 feet to the ground below.
Recent events (1)
- — Z (S) $1475
1926.454 A
- Issued
- Jun 29, 2020
- Abate by
- Jul 21, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold(s) trained by a person qualified in the subject matter to recognize those hazards associated with the type of scaffold(s) being used and to understand the procedures to control or minimize those hazards: On the east side of the construction, the employer did not ensure that employees who worked from scaffolds were trained to recognize hazards associated with the type of scaffold being used. The employees performing masonry work were exposed to a fall hazards of approximately 13-feet to the concrete or ground below.
Recent events (1)
- — Z (S) $0
1926.405 G02 IV
- Issued
- Jun 29, 2020
- Penalty
- Initial $276 · Current $276
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws. On the east side of the construction, employees using an extension cord with the outer sheathing pulled away to energize a DeWalt skill saw were exposed to electrical shock hazards.
Recent events (1)
- — Z (O) $276
More inspections at Ochoa Construction, LLC
View Ochoa Construction, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344796248.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.