COLUMBUS, OH ·
OSHA Inspection: ACCURATE CHIMNEY & FIREPLACE LTD.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of ACCURATE CHIMNEY & FIREPLACE LTD. in 307 W HUBBARD AVENUE, COLUMBUS, OH 43215 (NAICS 238140). OSHA activity number 344796909.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACCURATE CHIMNEY & FIREPLACE LTD.
- Site address
- 307 W HUBBARD AVENUE
- City
- COLUMBUS
- State
- OH
- ZIP
- 43215
- Mailing
- 14575 COMMERCIAL POINT ROAD, ASHVILLE, OH 43103
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (J)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 2
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Jul 9, 2020
- Abate by
- Jul 21, 2020
- Penalty
- Initial $4,048 · Current $2,024 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. a. On or about June 10, 2020, two employees were working from a pre-existing residential structure performing work on a chimney with no fall protection measures in place. The employees were exposed to fall hazards while working at heights of approximately 20 feet.
Recent events (2)
- · I (S) $2024
- · Z (S) $4048
1926.1053 B01
- Issued
- Jul 9, 2020
- Penalty
- Initial $4,048 · Current $2,024 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a. On or about June 10, 2020, two employees were using a portable ladder for access to the roof in which they were working that did not extend at least 3 feet above the upper landing surface. The ladder did not have a grasping device to assist employees in mounting and dismounting the ladder in use.
Recent events (2)
- · I (S) $2024
- · Z (S) $4048