Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CENTERPOINT ENERGY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CENTERPOINT ENERGY, INC. in INTERSECTION OF EDGEWOOD DRIVE AND WINWOOD LANE, MAUMELLE, AR 72113 (NAICS 221210). OSHA activity number 344797444.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Centerpoint Energy, INC. — free Get an email when a new federal OSHA severe-injury report for Centerpoint Energy, INC. is published. One employer, no account, unsubscribe in one click.
Site address
INTERSECTION OF EDGEWOOD DRIVE AND WINWOOD LANE
City
MAUMELLE
State
AR
ZIP
72113
Mailing
1515 E 15TH STREET, LITTLE ROCK, AR 72202
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221210
Employees
150
Ownership type
A

4 citations on file for this inspection.

1926.403 B01 II

Deleted Serious Gravity 1 1 instance 4 exposed
Issued
Dec 17, 2020
Abate by
Dec 30, 2020
Penalty
Initial $6,361 · Current $0 Reduced
29 CFR  1926.403(b)(1)(ii): Safety of equipment was not determined on the basis of mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:   On or about June 18, 2020, the employer did not ensure that flexible cord connectors maintained connectivity as designed.  This condition exposed employees to electrical shock and fire hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $6361
  • — Z (S) $6361

1926.21 B02

Serious Gravity 10 1 instance 4 exposed
Issued
Dec 17, 2020
Abate by
Jun 1, 2021
Penalty
Initial $13,494 · Current $13,394 Reduced

Hazardous substances 13408890

29 CFR  1926.21(b)(2):  The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury:     On or about June 18, 2020, employees welding and grinding in a trench were exposed to the hazards of thermal burns. The employer had not effectively communicated to the employees the safety hazards related to using a gas-powered fan in the presence of flammable gases and other ignition sources.
Recent events (3)
  • — F (S) $13394
  • — C (S) $13494
  • — Z (S) $13494

1926.57 C

Serious Gravity 10 1 instance 4 exposed
Issued
Dec 17, 2020
Abate by
Dec 30, 2020
Penalty
Initial $13,494 · Current $0 Reduced

Hazardous substances 13408890

29 CFR  1926.57(c):  Exhaust ventilation system component(s) were not designed, constructed, maintained, or operated to ensure the required protection for employee(s) from air contaminant(s) by maintaining airflow sufficient to gather air contaminants from said equipment or process and/or to convey them to suitable points of safe disposal:  On or about June 18, 20202, a gas-powered Honda GX390, model 730G4-H fan used to convey gas vapors away from employees was not used in such a way as to provide protection from hazards arising from the flammability of gas and other ignition sources. This practice created a condition that exposed employees to thermal burns.
Recent events (3)
  • — F (S) $0
  • — C (S) $13494
  • — Z (S) $13494

1926.651 C02

Other-than-serious Gravity 10 1 instance 4 exposed
Issued
Dec 17, 2020
Abate by
Dec 30, 2020
Penalty
Initial $13,494 · Current $13,394 Reduced
29 CFR  1926.651(c)(2):  A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  On or about June 18, 2020, employees repairing  a 2-inch gas line leak inside an unprotected trench approximately 6-feet in depth were using the sides of the trench as a means of egress, which enhanced the potential for tripping, slipping, or falling while trying to climb out of the trench in an emergency.
Recent events (3)
  • — F (O) $13394
  • — C (S) $13494
  • — Z (S) $13494

View Centerpoint Energy, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344797444.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.