Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MWH CONSTRUCTORS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MWH CONSTRUCTORS, INC. in 6450 YORK STREET, DENVER, CO 80229 (NAICS 237110). OSHA activity number 344797774.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MWH Constructors, INC. — free Get an email when a new federal OSHA severe-injury report for MWH Constructors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6450 YORK STREET
City
DENVER
State
CO
ZIP
80229
Mailing
370 INTERLOCKEN BOULEVARD, SUITE 400, BROOMFIELD, CO 80021
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
20
Ownership type
A

9 citations on file for this inspection.

1910.134 E01

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Nov 9, 2020
Abate by
Jan 31, 2022
Penalty
Initial $6,554 · Current $5,171 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested, or required to use the respirator in the workplace:  (a)  MWH Constructors, Inc., at 6450 York Street, Denver, CO:  On and preceding 6/16/2020, MWH Constructors, Inc. did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested, or required to use the respirator in the workplace.  Two employees removed concrete pads for HVAC units on the roof of the SLP building.  The employees used a jackhammer to remove concrete.  The employer required that the employees wear Moldex 2300N95 filtering facepiece respirators.  The employees did not receive medical evaluations.  This condition exposed the employees to a respiratory hazard.
Recent events (3)
  • — F (O) $5171
  • — C (S) $6554
  • — Z (S) $6554

1910.134 F02

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Nov 9, 2020
Abate by
Jan 31, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): The employer did not ensure that employees using a tight-fitting facepiece respirator were fit tested prior to initial use of the respirator, whenever a different respirator facepiece was used, and at least annually thereafter:  (a)  MWH Constructors, Inc., at 6450 York Street, Denver, CO:  On and preceding 6/16/2020, MWH Constructors, Inc. did not ensure that employees using a tight-fitting facepiece respirator were fit tested prior to initial use of the respirator, whenever a different respirator facepiece was used, and at least annually thereafter.  Two employees used a jackhammer to remove concrete pads for HVAC units on the roof of the SLP building.  Respiratory protection is required to be worn by workers when exposed to respirable crystalline silica when working outdoors using a jackhammer for greater than four hours per shift.  The employees, who were required to wear respiratory protection, did not receive fit tests.  This condition exposed the employees to a respiratory hazard.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 K01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Nov 9, 2020
Abate by
Nov 30, 2020
Penalty
Initial $6,554 · Current $0 Reduced
29 CFR 1910.134(k)(1): The employer did not provide effective, comprehensive, understandable, annual respirator training to employees who are required to use respirators:  (a)  MWH Constructors, Inc., at 6450 York Street, Denver, CO:  On and preceding 6/16/2020, MWH Constructors, Inc. did not provide effective, comprehensive, understandable, annual respirator training to employees who are required to use respirators.  Two employees removed concrete pads for HVAC units on the roof of the SLP building.  The employees used a jackhammer to remove concrete.  The employer required that the employees wear Moldex 2300N95 filtering facepiece respirators.  The employees did not receive respiratory protection training.  This condition exposed the employees to a respiratory hazard.
Recent events (3)
  • — F (S) $0
  • — C (S) $6554
  • — Z (S) $6554

1926.1153 I02 I A

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Nov 9, 2020
Abate by
Jan 31, 2022
Penalty
Initial $0 · Current $5,171
29 CFR 1926.1153(i)(2)(i)(A): The employer did not ensure that each employee covered by this section could demonstrate knowledge and understanding of the health hazards associated with exposure to respirable crystalline silica:  (a)  MWH Constructors, Inc., at 6450 York Street, Denver, CO:  On and preceding 6/16/2020, MWH Constructors, Inc. did not ensure that each employee covered by this section could demonstrate knowledge and understanding of the health hazards associated with exposure to respirable crystalline silica.  Two employees removed concrete pads for HVAC units on the roof of the SLP building.  The employees used a jackhammer to remove concrete.  Concrete contains respirable crystalline silica.  The employees did not receive training regarding the health hazards of respirable crystalline silica.  This condition exposed the employees to a respirable crystalline silica hazard.
Recent events (3)
  • — F (O) $5171
  • — C (S) $0
  • — Z (S) $0

1926.1153 I02 I C

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Nov 9, 2020
Abate by
Jan 31, 2022
Penalty
Initial $0 · Current $0
29 CFR 1926.1153(i)(2)(i)(C): The employer did not ensure that each employee covered by this section could demonstrate knowledge and understanding of specific measures the employer has implemented to protect employees from exposure to respirable crystalline silica, including engineering controls, work practices, and respirators to be used:  (a)  MWH Constructors, Inc., at 6450 York Street, Denver, CO:  On and preceding 6/16/2020, MWH Constructors, Inc. did not ensure that each employee covered by this section could demonstrate knowledge and understanding of specific measures the employer has implemented to protect employees from exposure to respirable crystalline silica, including engineering controls, work practices, and respirators to be used.  Two employees removed concrete pads for HVAC units on the roof of the SLP building.  The employees used a jackhammer to remove concrete.  Concrete contains respirable crystalline silica.  The employees did not receive training regarding effective engineering controls and work practices.  This condition exposed the employees to a respirable crystalline silica hazard.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1926.501 B10

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 9, 2020
Penalty
Initial $8,193 · Current $6,477 Reduced
29 C.F.R  1926.501(b)(10)   "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.   (a)  MWH Constructors, Inc., at 6450 York Street, Denver, CO:  On and preceding 6/16/2020, MWH Constructors, Inc. did not ensure that each employee on a walking/working surface having an unprotected side or edge which was six feet (1.8m) or more above a lower level was protected from falling by the use of a guardrail system, a safety net system, or personal fall arrest system.  Two employees removed concrete pads for HVAC units on the roof of the SLP building.  The employees used a jackhammer to remove concrete, and during the activity worked in proximity to the approximate one foot tall parapet.  The employees were not protected by a guardrail, safety net, or personal fall arrest system.  This condition exposed the employees to an approximate twenty-two foot fall hazard.
Recent events (3)
  • — F (S) $6477
  • — C (S) $8193
  • — Z (S) $8193

1926.1153 C01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Nov 9, 2020
Abate by
Nov 30, 2020
Penalty
Initial $6,554 · Current $0 Reduced
29 CFR 1926.1153(c)(1): For each employee engaged in a task identified on Table 1, the employer did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1:    (a)  MWH Constructors, Inc., at 6450 York Street, Denver, CO:  On and preceding 6/16/2020, for each employee engaged in a task identified on Table 1, MWH Constructors, Inc. did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, in that for a jackhammer operation, the tool was not used with a water delivery system that supplied a continuous stream or spray of water at the point of impact.  Two employees removed concrete pads for HVAC units on the roof of the SLP building.  The employees used a jackhammer to remove concrete.  Concrete contains respirable crystalline silica.  Employees utilized a hand pumped 3.5 gallon capacity water tank to control dust generated by the action of the jackhammer.  The 3.5 gallon hand pumped water tank did not fully and properly implement the engineering controls specified for jackhammer use on Table 1.  This condition exposed the employees to a respirable crystalline silica hazard.
Recent events (3)
  • — F (S) $0
  • — C (S) $6554
  • — Z (S) $6554

1926.1153 D02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 9, 2020
Abate by
Jan 31, 2022
Penalty
Initial $0 · Current $5,171
29 CFR 1926.1153(d)(2)(i): The employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2)(ii) or the scheduled monitoring option in paragraph (d)(2)(iii) of this section:  (a)  MWH Constructors, Inc., at 6450 York Street, Denver, CO:  On and preceding 6/16/2020, MWH Constructors, Inc. did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2)(ii) or the scheduled monitoring option in paragraph (d)(2)(iii) of this section.  Two employees removed concrete pads for HVAC units on the roof of the SLP building.  The employees used a jackhammer to remove concrete.  Concrete contains respirable crystalline silica.  The employer did not ensure that employees fully and properly implemented the engineering controls specified for jackhammer use on Table 1.  The employer did not evaluate employee exposure to respirable crystalline silica.  This condition exposed the employees to a respirable crystalline silica hazard.
Recent events (3)
  • — F (S) $5171
  • — C (S) $0
  • — Z (S) $0

1926.405 G02 IV

Deleted Other-than-serious 1 instance 1 exposed
Issued
Nov 9, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief was provided to prevent pull from being directly transmitted to joints or terminal screws:  (a)  MWH Constructors, Inc., at 6450 York Street, Denver, CO:  On 6/16/2020, MWH Constructors, Inc. did not ensure that flexible cords were connected to devices and fittings so that strain relief was provided to prevent pull from being directly transmitted to joints or terminal screws.  An employee set up fans in the BDSF building to provide ventilation during painting of walls.  A TPI Corporation fan, model PS42-D, had its flexible power cord pulled from the fitting, exposing the conductors.  The employer did not ensure that strain relief had been provided at the fitting for the electrical cord opening for the fan, preventing the cord from being pulled outward, exposing the conductors.  This condition potentially exposed the employee to an electrical hazard.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View MWH Constructors, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344797774.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.